mac80211: Add timeout to BA session start API
Allow drivers or rate control algorithms to specify BlockAck session timeout when initiating an ADDBA transaction. This is useful in cases where maintaining persistent BA sessions does not incur any overhead. The current timeout value of 5000 TUs is retained for all non ath9k/ath9k_htc drivers. Signed-off-by: Sujith Manoharan <Sujith.Manoharan@atheros.com> Reviewed-by: Johannes Berg <johannes@sipsolutions.net> Signed-off-by: John W. Linville <linville@tuxdriver.com>
Diffstat (limited to 'net/mac80211/rc80211_minstrel_ht.c')
-rw-r--r--net/mac80211/rc80211_minstrel_ht.c2
1 files changed, 1 insertions, 1 deletions
diff --git a/net/mac80211/rc80211_minstrel_ht.c b/net/mac80211/rc80211_minstrel_ht.c
index 4ad7a362fcc1..165a4518bb48 100644
--- a/net/mac80211/rc80211_minstrel_ht.c
+++ b/net/mac80211/rc80211_minstrel_ht.c
@@ -374,7 +374,7 @@ minstrel_aggr_check(struct minstrel_priv *mp, struct ieee80211_sta *pubsta, stru
if (skb_get_queue_mapping(skb) == IEEE80211_AC_VO)
return;
- ieee80211_start_tx_ba_session(pubsta, tid);
+ ieee80211_start_tx_ba_session(pubsta, tid, 5000);
}