summaryrefslogtreecommitdiffstats
path: root/kernel
diff options
context:
space:
mode:
authorMax Krasnyansky <maxk@qualcomm.com>2008-08-29 13:11:41 -0700
committerIngo Molnar <mingo@elte.hu>2008-09-06 19:22:15 +0200
commitdfb512ec4834116124da61d6c1ee10fd0aa32bd6 (patch)
treeea4f847f2a29face1b5774c6d44ec41bf92e302b /kernel
parentcf417141cbb3a4ceb5cca15b2c1f099bd0a6603c (diff)
downloadblackbird-op-linux-dfb512ec4834116124da61d6c1ee10fd0aa32bd6.tar.gz
blackbird-op-linux-dfb512ec4834116124da61d6c1ee10fd0aa32bd6.zip
sched: arch_reinit_sched_domains() must destroy domains to force rebuild
What I realized recently is that calling rebuild_sched_domains() in arch_reinit_sched_domains() by itself is not enough when cpusets are enabled. partition_sched_domains() code is trying to avoid unnecessary domain rebuilds and will not actually rebuild anything if new domain masks match the old ones. What this means is that doing echo 1 > /sys/devices/system/cpu/sched_mc_power_savings on a system with cpusets enabled will not take affect untill something changes in the cpuset setup (ie new sets created or deleted). This patch fixes restore correct behaviour where domains must be rebuilt in order to enable MC powersaving flags. Test on quad-core Core2 box with both CONFIG_CPUSETS and !CONFIG_CPUSETS. Also tested on dual-core Core2 laptop. Lockdep is happy and things are working as expected. Signed-off-by: Max Krasnyansky <maxk@qualcomm.com> Tested-by: Vaidyanathan Srinivasan <svaidy@linux.vnet.ibm.com> Signed-off-by: Ingo Molnar <mingo@elte.hu>
Diffstat (limited to 'kernel')
-rw-r--r--kernel/sched.c19
1 files changed, 13 insertions, 6 deletions
diff --git a/kernel/sched.c b/kernel/sched.c
index d601fb0406ca..d72ee9a0eacd 100644
--- a/kernel/sched.c
+++ b/kernel/sched.c
@@ -7589,24 +7589,27 @@ static int dattrs_equal(struct sched_domain_attr *cur, int idx_cur,
* and partition_sched_domains() will fallback to the single partition
* 'fallback_doms', it also forces the domains to be rebuilt.
*
+ * If doms_new==NULL it will be replaced with cpu_online_map.
+ * ndoms_new==0 is a special case for destroying existing domains.
+ * It will not create the default domain.
+ *
* Call with hotplug lock held
*/
void partition_sched_domains(int ndoms_new, cpumask_t *doms_new,
struct sched_domain_attr *dattr_new)
{
- int i, j;
+ int i, j, n;
mutex_lock(&sched_domains_mutex);
/* always unregister in case we don't destroy any domains */
unregister_sched_domain_sysctl();
- if (doms_new == NULL)
- ndoms_new = 0;
+ n = doms_new ? ndoms_new : 0;
/* Destroy deleted domains */
for (i = 0; i < ndoms_cur; i++) {
- for (j = 0; j < ndoms_new; j++) {
+ for (j = 0; j < n; j++) {
if (cpus_equal(doms_cur[i], doms_new[j])
&& dattrs_equal(dattr_cur, i, dattr_new, j))
goto match1;
@@ -7619,7 +7622,6 @@ match1:
if (doms_new == NULL) {
ndoms_cur = 0;
- ndoms_new = 1;
doms_new = &fallback_doms;
cpus_andnot(doms_new[0], cpu_online_map, cpu_isolated_map);
dattr_new = NULL;
@@ -7656,8 +7658,13 @@ match2:
int arch_reinit_sched_domains(void)
{
get_online_cpus();
+
+ /* Destroy domains first to force the rebuild */
+ partition_sched_domains(0, NULL, NULL);
+
rebuild_sched_domains();
put_online_cpus();
+
return 0;
}
@@ -7741,7 +7748,7 @@ static int update_sched_domains(struct notifier_block *nfb,
case CPU_ONLINE_FROZEN:
case CPU_DEAD:
case CPU_DEAD_FROZEN:
- partition_sched_domains(0, NULL, NULL);
+ partition_sched_domains(1, NULL, NULL);
return NOTIFY_OK;
default:
OpenPOWER on IntegriCloud