authorDave Liu <daveliu@freescale.com>2010-01-06 20:32:38 -0800
committerDavid S. Miller <davem@davemloft.net>2010-01-06 20:32:38 -0800
commit58933c643f86651decc4818cf680f9ec3b0460d2 (patch)
treef243887c20ae3f77c14dde00b923cda147ce4f9b /drivers
parentd3af9dd04f8795dc2761ecfa56632e4d0df0dae2 (diff)
downloadblackbird-op-linux-58933c643f86651decc4818cf680f9ec3b0460d2.tar.gz
blackbird-op-linux-58933c643f86651decc4818cf680f9ec3b0460d2.zip
ucc_geth: Fix the wrong the Rx/Tx FIFO size
current the Rx/Tx FIFO size settings cause problem when four UEC ethernets work simultaneously. eg: GETH1, UEM-J15, GETH2, UEC-J5 on 8569MDS board $ ifconfig eth0 10.193.20.166 $ ifconfig eth1 10.193.20.167 $ ifconfig eth2 10.193.20.168 then $ ifconfig eth3 10.193.20.169 The fourth ethernet will cause all of interface broken, you cann't ping successfully any more. The patch fix this issue for MPC8569 Rev1.0 and Rev2.0 Signed-off-by: Dave Liu <daveliu@freescale.com> Acked-by: Anton Vorontsov <avorontsov@ru.mvista.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers')
-rw-r--r--drivers/net/ucc_geth.h13
1 files changed, 7 insertions, 6 deletions
diff --git a/drivers/net/ucc_geth.h b/drivers/net/ucc_geth.h
index a007e2acf651..ef1fbeb11c6e 100644
--- a/drivers/net/ucc_geth.h
+++ b/drivers/net/ucc_geth.h
@@ -838,13 +838,13 @@ struct ucc_geth_hardware_statistics {
using the maximum is
easier */
#define UCC_GETH_SEND_QUEUE_QUEUE_DESCRIPTOR_ALIGNMENT 32
-#define UCC_GETH_SCHEDULER_ALIGNMENT 4 /* This is a guess */
+#define UCC_GETH_SCHEDULER_ALIGNMENT 8 /* This is a guess */
#define UCC_GETH_TX_STATISTICS_ALIGNMENT 4 /* This is a guess */
#define UCC_GETH_RX_STATISTICS_ALIGNMENT 4 /* This is a guess */
#define UCC_GETH_RX_INTERRUPT_COALESCING_ALIGNMENT 64
#define UCC_GETH_RX_BD_QUEUES_ALIGNMENT 8 /* This is a guess */
#define UCC_GETH_RX_PREFETCHED_BDS_ALIGNMENT 128 /* This is a guess */
-#define UCC_GETH_RX_EXTENDED_FILTERING_GLOBAL_PARAMETERS_ALIGNMENT 4 /* This
+#define UCC_GETH_RX_EXTENDED_FILTERING_GLOBAL_PARAMETERS_ALIGNMENT 8 /* This
is a
guess
*/
@@ -899,16 +899,17 @@ struct ucc_geth_hardware_statistics {
#define UCC_GETH_UTFS_INIT 512 /* Tx virtual FIFO size
*/
#define UCC_GETH_UTFET_INIT 256 /* 1/2 utfs */
-#define UCC_GETH_UTFTT_INIT 128
+#define UCC_GETH_UTFTT_INIT 512
/* Gigabit Ethernet (1000 Mbps) */
#define UCC_GETH_URFS_GIGA_INIT 4096/*2048*/ /* Rx virtual
FIFO size */
#define UCC_GETH_URFET_GIGA_INIT 2048/*1024*/ /* 1/2 urfs */
#define UCC_GETH_URFSET_GIGA_INIT 3072/*1536*/ /* 3/4 urfs */
-#define UCC_GETH_UTFS_GIGA_INIT 8192/*2048*/ /* Tx virtual
+#define UCC_GETH_UTFS_GIGA_INIT 4096/*2048*/ /* Tx virtual
+ FIFO size */
+#define UCC_GETH_UTFET_GIGA_INIT 2048/*1024*/ /* 1/2 utfs */
+#define UCC_GETH_UTFTT_GIGA_INIT 4096/*0x40*/ /* Tx virtual
FIFO size */
-#define UCC_GETH_UTFET_GIGA_INIT 4096/*1024*/ /* 1/2 utfs */
-#define UCC_GETH_UTFTT_GIGA_INIT 0x400/*0x40*/ /* */
#define UCC_GETH_REMODER_INIT 0 /* bits that must be
set */