summaryrefslogtreecommitdiffstats
path: root/drivers/w1/masters
diff options
context:
space:
mode:
authorJean Delvare <khali@linux-fr.org>2008-07-16 19:30:07 +0200
committerJean Delvare <khali@mahadeva.delvare>2008-07-16 19:30:07 +0200
commit61c91f7ded640bb2b340cc89d9ca3a3ca0229c74 (patch)
tree8d5baf0685008a5bf55802184ac203101f65f970 /drivers/w1/masters
parentbd8d421f7ca9f8da3d820d28379d796500f69529 (diff)
downloadblackbird-op-linux-61c91f7ded640bb2b340cc89d9ca3a3ca0229c74.tar.gz
blackbird-op-linux-61c91f7ded640bb2b340cc89d9ca3a3ca0229c74.zip
w1/ds2482: Convert to a new-style driver
The new-style ds2482 driver implements the optional detect() callback to cover the use cases of the legacy driver. I'm curious if anyone really needs this though, so it might be removed in the feature. Signed-off-by: Jean Delvare <khali@linux-fr.org>
Diffstat (limited to 'drivers/w1/masters')
-rw-r--r--drivers/w1/masters/ds2482.c104
1 files changed, 44 insertions, 60 deletions
diff --git a/drivers/w1/masters/ds2482.c b/drivers/w1/masters/ds2482.c
index 0fd5820d5c61..df52cb355f7d 100644
--- a/drivers/w1/masters/ds2482.c
+++ b/drivers/w1/masters/ds2482.c
@@ -94,21 +94,31 @@ static const u8 ds2482_chan_rd[8] =
#define DS2482_REG_STS_1WB 0x01
-static int ds2482_attach_adapter(struct i2c_adapter *adapter);
-static int ds2482_detect(struct i2c_adapter *adapter, int address, int kind);
-static int ds2482_detach_client(struct i2c_client *client);
+static int ds2482_probe(struct i2c_client *client,
+ const struct i2c_device_id *id);
+static int ds2482_detect(struct i2c_client *client, int kind,
+ struct i2c_board_info *info);
+static int ds2482_remove(struct i2c_client *client);
/**
* Driver data (common to all clients)
*/
+static const struct i2c_device_id ds2482_id[] = {
+ { "ds2482", 0 },
+ { }
+};
+
static struct i2c_driver ds2482_driver = {
.driver = {
.owner = THIS_MODULE,
.name = "ds2482",
},
- .attach_adapter = ds2482_attach_adapter,
- .detach_client = ds2482_detach_client,
+ .probe = ds2482_probe,
+ .remove = ds2482_remove,
+ .id_table = ds2482_id,
+ .detect = ds2482_detect,
+ .address_data = &addr_data,
};
/*
@@ -124,7 +134,7 @@ struct ds2482_w1_chan {
};
struct ds2482_data {
- struct i2c_client client;
+ struct i2c_client *client;
struct mutex access_lock;
/* 1-wire interface(s) */
@@ -147,7 +157,7 @@ struct ds2482_data {
static inline int ds2482_select_register(struct ds2482_data *pdev, u8 read_ptr)
{
if (pdev->read_prt != read_ptr) {
- if (i2c_smbus_write_byte_data(&pdev->client,
+ if (i2c_smbus_write_byte_data(pdev->client,
DS2482_CMD_SET_READ_PTR,
read_ptr) < 0)
return -1;
@@ -167,7 +177,7 @@ static inline int ds2482_select_register(struct ds2482_data *pdev, u8 read_ptr)
*/
static inline int ds2482_send_cmd(struct ds2482_data *pdev, u8 cmd)
{
- if (i2c_smbus_write_byte(&pdev->client, cmd) < 0)
+ if (i2c_smbus_write_byte(pdev->client, cmd) < 0)
return -1;
pdev->read_prt = DS2482_PTR_CODE_STATUS;
@@ -187,7 +197,7 @@ static inline int ds2482_send_cmd(struct ds2482_data *pdev, u8 cmd)
static inline int ds2482_send_cmd_data(struct ds2482_data *pdev,
u8 cmd, u8 byte)
{
- if (i2c_smbus_write_byte_data(&pdev->client, cmd, byte) < 0)
+ if (i2c_smbus_write_byte_data(pdev->client, cmd, byte) < 0)
return -1;
/* all cmds leave in STATUS, except CONFIG */
@@ -216,7 +226,7 @@ static int ds2482_wait_1wire_idle(struct ds2482_data *pdev)
if (!ds2482_select_register(pdev, DS2482_PTR_CODE_STATUS)) {
do {
- temp = i2c_smbus_read_byte(&pdev->client);
+ temp = i2c_smbus_read_byte(pdev->client);
} while ((temp >= 0) && (temp & DS2482_REG_STS_1WB) &&
(++retries < DS2482_WAIT_IDLE_TIMEOUT));
}
@@ -238,13 +248,13 @@ static int ds2482_wait_1wire_idle(struct ds2482_data *pdev)
*/
static int ds2482_set_channel(struct ds2482_data *pdev, u8 channel)
{
- if (i2c_smbus_write_byte_data(&pdev->client, DS2482_CMD_CHANNEL_SELECT,
+ if (i2c_smbus_write_byte_data(pdev->client, DS2482_CMD_CHANNEL_SELECT,
ds2482_chan_wr[channel]) < 0)
return -1;
pdev->read_prt = DS2482_PTR_CODE_CHANNEL;
pdev->channel = -1;
- if (i2c_smbus_read_byte(&pdev->client) == ds2482_chan_rd[channel]) {
+ if (i2c_smbus_read_byte(pdev->client) == ds2482_chan_rd[channel]) {
pdev->channel = channel;
return 0;
}
@@ -368,7 +378,7 @@ static u8 ds2482_w1_read_byte(void *data)
ds2482_select_register(pdev, DS2482_PTR_CODE_DATA);
/* Read the data byte */
- result = i2c_smbus_read_byte(&pdev->client);
+ result = i2c_smbus_read_byte(pdev->client);
mutex_unlock(&pdev->access_lock);
@@ -415,47 +425,38 @@ static u8 ds2482_w1_reset_bus(void *data)
}
-/**
- * Called to see if the device exists on an i2c bus.
- */
-static int ds2482_attach_adapter(struct i2c_adapter *adapter)
+static int ds2482_detect(struct i2c_client *client, int kind,
+ struct i2c_board_info *info)
{
- return i2c_probe(adapter, &addr_data, ds2482_detect);
-}
+ if (!i2c_check_functionality(client->adapter,
+ I2C_FUNC_SMBUS_WRITE_BYTE_DATA |
+ I2C_FUNC_SMBUS_BYTE))
+ return -ENODEV;
+ strlcpy(info->type, "ds2482", I2C_NAME_SIZE);
-/*
- * The following function does more than just detection. If detection
- * succeeds, it also registers the new chip.
- */
-static int ds2482_detect(struct i2c_adapter *adapter, int address, int kind)
+ return 0;
+}
+
+static int ds2482_probe(struct i2c_client *client,
+ const struct i2c_device_id *id)
{
struct ds2482_data *data;
- struct i2c_client *new_client;
- int err = 0;
+ int err = -ENODEV;
int temp1;
int idx;
- if (!i2c_check_functionality(adapter,
- I2C_FUNC_SMBUS_WRITE_BYTE_DATA |
- I2C_FUNC_SMBUS_BYTE))
- goto exit;
-
if (!(data = kzalloc(sizeof(struct ds2482_data), GFP_KERNEL))) {
err = -ENOMEM;
goto exit;
}
- new_client = &data->client;
- i2c_set_clientdata(new_client, data);
- new_client->addr = address;
- new_client->driver = &ds2482_driver;
- new_client->adapter = adapter;
+ data->client = client;
+ i2c_set_clientdata(client, data);
/* Reset the device (sets the read_ptr to status) */
if (ds2482_send_cmd(data, DS2482_CMD_RESET) < 0) {
- dev_dbg(&adapter->dev, "DS2482 reset failed at 0x%02x.\n",
- address);
+ dev_warn(&client->dev, "DS2482 reset failed.\n");
goto exit_free;
}
@@ -463,10 +464,10 @@ static int ds2482_detect(struct i2c_adapter *adapter, int address, int kind)
ndelay(525);
/* Read the status byte - only reset bit and line should be set */
- temp1 = i2c_smbus_read_byte(new_client);
+ temp1 = i2c_smbus_read_byte(client);
if (temp1 != (DS2482_REG_STS_LL | DS2482_REG_STS_RST)) {
- dev_dbg(&adapter->dev, "DS2482 (0x%02x) reset status "
- "0x%02X - not a DS2482\n", address, temp1);
+ dev_warn(&client->dev, "DS2482 reset status "
+ "0x%02X - not a DS2482\n", temp1);
goto exit_free;
}
@@ -478,16 +479,8 @@ static int ds2482_detect(struct i2c_adapter *adapter, int address, int kind)
/* Set all config items to 0 (off) */
ds2482_send_cmd_data(data, DS2482_CMD_WRITE_CONFIG, 0xF0);
- /* We can fill in the remaining client fields */
- snprintf(new_client->name, sizeof(new_client->name), "ds2482-%d00",
- data->w1_count);
-
mutex_init(&data->access_lock);
- /* Tell the I2C layer a new client has arrived */
- if ((err = i2c_attach_client(new_client)))
- goto exit_free;
-
/* Register 1-wire interface(s) */
for (idx = 0; idx < data->w1_count; idx++) {
data->w1_ch[idx].pdev = data;
@@ -511,8 +504,6 @@ static int ds2482_detect(struct i2c_adapter *adapter, int address, int kind)
return 0;
exit_w1_remove:
- i2c_detach_client(new_client);
-
for (idx = 0; idx < data->w1_count; idx++) {
if (data->w1_ch[idx].pdev != NULL)
w1_remove_master_device(&data->w1_ch[idx].w1_bm);
@@ -523,10 +514,10 @@ exit:
return err;
}
-static int ds2482_detach_client(struct i2c_client *client)
+static int ds2482_remove(struct i2c_client *client)
{
struct ds2482_data *data = i2c_get_clientdata(client);
- int err, idx;
+ int idx;
/* Unregister the 1-wire bridge(s) */
for (idx = 0; idx < data->w1_count; idx++) {
@@ -534,13 +525,6 @@ static int ds2482_detach_client(struct i2c_client *client)
w1_remove_master_device(&data->w1_ch[idx].w1_bm);
}
- /* Detach the i2c device */
- if ((err = i2c_detach_client(client))) {
- dev_err(&client->dev,
- "Deregistration failed, client not detached.\n");
- return err;
- }
-
/* Free the memory */
kfree(data);
return 0;
OpenPOWER on IntegriCloud