summaryrefslogtreecommitdiffstats
path: root/drivers/spi
diff options
context:
space:
mode:
authorLinus Torvalds <torvalds@linux-foundation.org>2012-01-09 14:30:28 -0800
committerLinus Torvalds <torvalds@linux-foundation.org>2012-01-09 14:30:28 -0800
commit190a44e65b0f32eaf5b4db3969f5eb224f83a7a2 (patch)
tree577c9a3949ba06e62d082eb11894b7045ebe3ef3 /drivers/spi
parentdfc1ebe76663d582a01c9dc572395cf8086d01de (diff)
parentb48741cce3be32a48af9a2b272f3f13a077375cf (diff)
downloadblackbird-op-linux-190a44e65b0f32eaf5b4db3969f5eb224f83a7a2.tar.gz
blackbird-op-linux-190a44e65b0f32eaf5b4db3969f5eb224f83a7a2.zip
Merge tag 'cleanup2' of git://git.kernel.org/pub/scm/linux/kernel/git/arm/arm-soc
Cleanups for the Samsung platforms Various cleanup changes that the device driver changes are built upon. Since the samsung cleanups depend on the device tree series, which depends on the first set of cleanups for tegra. * tag 'cleanup2' of git://git.kernel.org/pub/scm/linux/kernel/git/arm/arm-soc: ARM: EXYNOS: Use gpio_request_one ARM: S5PV210: Use gpio_request_one ARM: S3C64XX: Modified according to SPI consolidation work ARM: S5PV210: Modified files for SPI consolidation work ARM: S5P64X0: Modified files for SPI consolidation work ARM: S5PC100: Modified files for SPI consolidation work ARM: S3C64XX: Modified files for SPI consolidation work ARM: SAMSUNG: Consolidation of SPI platform devices to plat-samsung ARM: SAMSUNG: Remove SPI bus clocks from platform data ARM: S5PV210: Add SPI clkdev support ARM: S5P64X0: Add SPI clkdev support ARM: S5PC100: Add SPI clkdev support ARM: S3C64XX: Add SPI clkdev support spi/s3c64xx: Use bus clocks created using clkdev mmc: sdhci-s3c: Use generic clock names for sdhci bus clock options ARM: SAMSUNG: Add lookup of sdhci-s3c clocks using generic names ARM: SAMSUNG: Remove SDHCI bus clocks from platform data ARM: SAMSUNG: Use kmemdup rather than duplicating its implementation ARM: EXYNOS: remove exynos4_scu_enable()
Diffstat (limited to 'drivers/spi')
-rw-r--r--drivers/spi/spi-s3c64xx.c14
1 files changed, 5 insertions, 9 deletions
diff --git a/drivers/spi/spi-s3c64xx.c b/drivers/spi/spi-s3c64xx.c
index 019a7163572f..dcf7e1006426 100644
--- a/drivers/spi/spi-s3c64xx.c
+++ b/drivers/spi/spi-s3c64xx.c
@@ -971,6 +971,7 @@ static int __init s3c64xx_spi_probe(struct platform_device *pdev)
struct s3c64xx_spi_info *sci;
struct spi_master *master;
int ret;
+ char clk_name[16];
if (pdev->id < 0) {
dev_err(&pdev->dev,
@@ -984,11 +985,6 @@ static int __init s3c64xx_spi_probe(struct platform_device *pdev)
}
sci = pdev->dev.platform_data;
- if (!sci->src_clk_name) {
- dev_err(&pdev->dev,
- "Board init must call s3c64xx_spi_set_info()\n");
- return -EINVAL;
- }
/* Check for availability of necessary resource */
@@ -1073,17 +1069,17 @@ static int __init s3c64xx_spi_probe(struct platform_device *pdev)
goto err4;
}
- sdd->src_clk = clk_get(&pdev->dev, sci->src_clk_name);
+ sprintf(clk_name, "spi_busclk%d", sci->src_clk_nr);
+ sdd->src_clk = clk_get(&pdev->dev, clk_name);
if (IS_ERR(sdd->src_clk)) {
dev_err(&pdev->dev,
- "Unable to acquire clock '%s'\n", sci->src_clk_name);
+ "Unable to acquire clock '%s'\n", clk_name);
ret = PTR_ERR(sdd->src_clk);
goto err5;
}
if (clk_enable(sdd->src_clk)) {
- dev_err(&pdev->dev, "Couldn't enable clock '%s'\n",
- sci->src_clk_name);
+ dev_err(&pdev->dev, "Couldn't enable clock '%s'\n", clk_name);
ret = -EBUSY;
goto err6;
}
OpenPOWER on IntegriCloud