summaryrefslogtreecommitdiffstats
path: root/drivers/power/bq27x00_battery.c
diff options
context:
space:
mode:
authorPali Rohár <pali.rohar@gmail.com>2011-11-01 01:43:05 +0100
committerAnton Vorontsov <cbouatmailru@gmail.com>2011-11-25 23:58:16 +0400
commit4b226c2cf04eb373369d298fa00181b0eec71233 (patch)
tree63fd6b047b61b29c4e4352a41f4a1f0b4f5dc0b9 /drivers/power/bq27x00_battery.c
parentd66bab3f3a5119084ac0ed010a7eae0000af4f16 (diff)
downloadblackbird-op-linux-4b226c2cf04eb373369d298fa00181b0eec71233.tar.gz
blackbird-op-linux-4b226c2cf04eb373369d298fa00181b0eec71233.zip
bq27x00_battery: Report -ENODATA if bq27000 battery was not calibrated
* CI (Capacity Inaccurate) flag is set after full reset on bq27000 battery * when is set, all capacity properties should be reported incorrectly, because there was no learning cycle and battery was not calibrated * instead reporting incorrect values, report -ENODATA Signed-off-by: Pali Rohár <pali.rohar@gmail.com> Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
Diffstat (limited to 'drivers/power/bq27x00_battery.c')
-rw-r--r--drivers/power/bq27x00_battery.c19
1 files changed, 14 insertions, 5 deletions
diff --git a/drivers/power/bq27x00_battery.c b/drivers/power/bq27x00_battery.c
index a5311225b964..6c8dfdb169a1 100644
--- a/drivers/power/bq27x00_battery.c
+++ b/drivers/power/bq27x00_battery.c
@@ -56,6 +56,7 @@
#define BQ27000_REG_ILMD 0x76 /* Initial last measured discharge */
#define BQ27000_FLAG_EDVF BIT(0) /* Final End-of-Discharge-Voltage flag */
#define BQ27000_FLAG_EDV1 BIT(1) /* First End-of-Discharge-Voltage flag */
+#define BQ27000_FLAG_CI BIT(4) /* Capacity Inaccurate flag */
#define BQ27000_FLAG_FC BIT(5)
#define BQ27000_FLAG_CHGS BIT(7) /* Charge state flag */
@@ -265,12 +266,20 @@ static void bq27x00_update(struct bq27x00_device_info *di)
cache.flags = bq27x00_read(di, BQ27x00_REG_FLAGS, is_bq27500);
if (cache.flags >= 0) {
- cache.capacity = bq27x00_battery_read_rsoc(di);
+ if (!is_bq27500 && (cache.flags & BQ27000_FLAG_CI)) {
+ cache.capacity = -ENODATA;
+ cache.time_to_empty = -ENODATA;
+ cache.time_to_empty_avg = -ENODATA;
+ cache.time_to_full = -ENODATA;
+ cache.charge_full = -ENODATA;
+ } else {
+ cache.capacity = bq27x00_battery_read_rsoc(di);
+ cache.time_to_empty = bq27x00_battery_read_time(di, BQ27x00_REG_TTE);
+ cache.time_to_empty_avg = bq27x00_battery_read_time(di, BQ27x00_REG_TTECP);
+ cache.time_to_full = bq27x00_battery_read_time(di, BQ27x00_REG_TTF);
+ cache.charge_full = bq27x00_battery_read_lmd(di);
+ }
cache.temperature = bq27x00_read(di, BQ27x00_REG_TEMP, false);
- cache.time_to_empty = bq27x00_battery_read_time(di, BQ27x00_REG_TTE);
- cache.time_to_empty_avg = bq27x00_battery_read_time(di, BQ27x00_REG_TTECP);
- cache.time_to_full = bq27x00_battery_read_time(di, BQ27x00_REG_TTF);
- cache.charge_full = bq27x00_battery_read_lmd(di);
cache.cycle_count = bq27x00_battery_read_cyct(di);
/* We only have to read charge design full once */
OpenPOWER on IntegriCloud