authorBreno Leitao <leitao@linux.vnet.ibm.com>2009-12-18 20:35:34 -0800
committerDavid S. Miller <davem@davemloft.net>2009-12-18 20:35:34 -0800
commite6bf95ffa8d6f8f4b7ee33ea01490d95b0bbeb6e (patch)
tree6a361fa1fde7ac2ce613d5ad88ff9b688c02f5ad /drivers/net
parent4773a47d8a564633cd80b94df397e91e946893e2 (diff)
downloadblackbird-op-linux-e6bf95ffa8d6f8f4b7ee33ea01490d95b0bbeb6e.tar.gz
blackbird-op-linux-e6bf95ffa8d6f8f4b7ee33ea01490d95b0bbeb6e.zip
bnx2: fixing a timout error due not refreshing TX timers correctly
When running the following script on an active bnx2 interface: while(true); do ifconfig ethX mtu 9000; ifconfig ethX mtu 1500; done A timeout error appears and dumps the following stack: NETDEV WATCHDOG: eth4 (bnx2): transmit queue 0 timed out ------------[ cut here ]------------ Badness at net/sched/sch_generic.c:261 <snip> This patch just fixes the way that ->trans_start is refreshed. Signed-off-by: Breno Leitao <leitao@linux.vnet.ibm.com> Acked-by: Michael Chan <mchan@broadcom.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net')
-rw-r--r--drivers/net/bnx2.c10
1 files changed, 9 insertions, 1 deletions
diff --git a/drivers/net/bnx2.c b/drivers/net/bnx2.c
index c3e2b279fca0..f38764ec02c3 100644
--- a/drivers/net/bnx2.c
+++ b/drivers/net/bnx2.c
@@ -654,9 +654,17 @@ bnx2_netif_stop(struct bnx2 *bp)
{
bnx2_cnic_stop(bp);
if (netif_running(bp->dev)) {
+ int i;
+
bnx2_napi_disable(bp);
netif_tx_disable(bp->dev);
- bp->dev->trans_start = jiffies; /* prevent tx timeout */
+ /* prevent tx timeout */
+ for (i = 0; i < bp->dev->num_tx_queues; i++) {
+ struct netdev_queue *txq;
+
+ txq = netdev_get_tx_queue(bp->dev, i);
+ txq->trans_start = jiffies;
+ }
}
}