ixgbe: disable flow control by default
Since the adapter cannot tell what the remote end's flow control capability is through auto-neg, we must turn off flow control by default. Signed-off-by: Jesse Brandeburg <jesse.brandeburg@intel.com> Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com> Signed-off-by: Jeff Garzik <jgarzik@redhat.com>
Diffstat (limited to 'drivers/net/ixgbe/ixgbe_common.c')
-rw-r--r--drivers/net/ixgbe/ixgbe_common.c17
1 files changed, 17 insertions, 0 deletions
diff --git a/drivers/net/ixgbe/ixgbe_common.c b/drivers/net/ixgbe/ixgbe_common.c
index a9f4d0e58e1c..9c0d0a1964eb 100644
--- a/drivers/net/ixgbe/ixgbe_common.c
+++ b/drivers/net/ixgbe/ixgbe_common.c
@@ -1065,6 +1065,13 @@ s32 ixgbe_setup_fc(struct ixgbe_hw *hw, s32 packetbuf_num)
rmcs_reg &= ~(IXGBE_RMCS_TFCE_PRIORITY | IXGBE_RMCS_TFCE_802_3X);
/*
+ * 10 gig parts do not have a word in the EEPROM to determine the
+ * default flow control setting, so we explicitly set it to full.
+ */
+ if (hw->fc.type == ixgbe_fc_default)
+ hw->fc.type = ixgbe_fc_full;
+
+ /*
* We want to save off the original Flow Control configuration just in
* case we get disconnected and then reconnected into a different hub
* or switch with different Flow Control capabilities.
@@ -1117,6 +1124,16 @@ s32 ixgbe_setup_fc(struct ixgbe_hw *hw, s32 packetbuf_num)
IXGBE_WRITE_REG(hw, IXGBE_RMCS, rmcs_reg);
/*
+ * Check for invalid software configuration, zeros are completely
+ * invalid for all parameters used past this point, and if we enable
+ * flow control with zero water marks, we blast flow control packets.
+ */
+ if (!hw->fc.low_water || !hw->fc.high_water || !hw->fc.pause_time) {
+ hw_dbg(hw, "Flow control structure initialized incorrectly\n");
+ return IXGBE_ERR_INVALID_LINK_SETTINGS;
+ }
+
+ /*
* We need to set up the Receive Threshold high and low water