diff options
author | Kleber Sacilotto de Souza <klebers@linux.vnet.ibm.com> | 2011-05-04 13:05:11 +0000 |
---|---|---|
committer | David S. Miller <davem@davemloft.net> | 2011-05-09 11:49:24 -0700 |
commit | dcbe14b91a920657ff3a9ba0efb7c5b5562f956a (patch) | |
tree | 169e1e674371320fa7a59e4c28681df324832c0e /drivers/net/ehea | |
parent | b9f47a3aaeabdce3b42829bbb27765fa340f76ba (diff) | |
download | blackbird-op-linux-dcbe14b91a920657ff3a9ba0efb7c5b5562f956a.tar.gz blackbird-op-linux-dcbe14b91a920657ff3a9ba0efb7c5b5562f956a.zip |
ehea: fix wrongly reported speed and port
Currently EHEA reports to ethtool as supporting 10M, 100M, 1G and
10G and connected to FIBRE independent of the hardware configuration.
However, when connected to FIBRE the only supported speed is 10G
full-duplex, and the other speeds and modes are only supported
when connected to twisted pair.
Signed-off-by: Kleber Sacilotto de Souza <klebers@linux.vnet.ibm.com>
Acked-by: Breno Leitao <leitao@linux.vnet.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net/ehea')
-rw-r--r-- | drivers/net/ehea/ehea_ethtool.c | 21 |
1 files changed, 13 insertions, 8 deletions
diff --git a/drivers/net/ehea/ehea_ethtool.c b/drivers/net/ehea/ehea_ethtool.c index 3e2e734fecb7..f3bbdcef338c 100644 --- a/drivers/net/ehea/ehea_ethtool.c +++ b/drivers/net/ehea/ehea_ethtool.c @@ -55,15 +55,20 @@ static int ehea_get_settings(struct net_device *dev, struct ethtool_cmd *cmd) cmd->duplex = -1; } - cmd->supported = (SUPPORTED_10000baseT_Full | SUPPORTED_1000baseT_Full - | SUPPORTED_100baseT_Full | SUPPORTED_100baseT_Half - | SUPPORTED_10baseT_Full | SUPPORTED_10baseT_Half - | SUPPORTED_Autoneg | SUPPORTED_FIBRE); - - cmd->advertising = (ADVERTISED_10000baseT_Full | ADVERTISED_Autoneg - | ADVERTISED_FIBRE); + if (cmd->speed == SPEED_10000) { + cmd->supported = (SUPPORTED_10000baseT_Full | SUPPORTED_FIBRE); + cmd->advertising = (ADVERTISED_10000baseT_Full | ADVERTISED_FIBRE); + cmd->port = PORT_FIBRE; + } else { + cmd->supported = (SUPPORTED_1000baseT_Full | SUPPORTED_100baseT_Full + | SUPPORTED_100baseT_Half | SUPPORTED_10baseT_Full + | SUPPORTED_10baseT_Half | SUPPORTED_Autoneg + | SUPPORTED_TP); + cmd->advertising = (ADVERTISED_1000baseT_Full | ADVERTISED_Autoneg + | ADVERTISED_TP); + cmd->port = PORT_TP; + } - cmd->port = PORT_FIBRE; cmd->autoneg = port->autoneg == 1 ? AUTONEG_ENABLE : AUTONEG_DISABLE; return 0; |