summaryrefslogtreecommitdiffstats
path: root/drivers/net/benet
diff options
context:
space:
mode:
authorAjit Khaparde <ajitk@serverengines.com>2009-11-06 02:06:59 +0000
committerDavid S. Miller <davem@davemloft.net>2009-11-06 20:26:03 -0800
commit9e90c961134929678022aee0c68b16c1ed520614 (patch)
treefee2dad0fcbfe8e5168edf9a394ecfa8061cc386 /drivers/net/benet
parentbb7b22840141a4fab8f232ee90d30cdf728bb032 (diff)
downloadblackbird-op-linux-9e90c961134929678022aee0c68b16c1ed520614.tar.gz
blackbird-op-linux-9e90c961134929678022aee0c68b16c1ed520614.zip
be2net: fix to set proper flow control on resume
If be2 goes into suspend after a user changes the flow control settings, we are not programming them back after resume. This patch takes care of it. We now get the flow control settings before going to suspend mode and then apply them during resume. Signed-off-by: Ajit Khaparde <ajitk@serverengines.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net/benet')
-rw-r--r--drivers/net/benet/be.h2
-rw-r--r--drivers/net/benet/be_ethtool.c8
-rw-r--r--drivers/net/benet/be_main.c8
3 files changed, 14 insertions, 4 deletions
diff --git a/drivers/net/benet/be.h b/drivers/net/benet/be.h
index a80da0e14a52..3b79a225628a 100644
--- a/drivers/net/benet/be.h
+++ b/drivers/net/benet/be.h
@@ -259,6 +259,8 @@ struct be_adapter {
u32 port_num;
bool promiscuous;
u32 cap;
+ u32 rx_fc; /* Rx flow control */
+ u32 tx_fc; /* Tx flow control */
};
extern const struct ethtool_ops be_ethtool_ops;
diff --git a/drivers/net/benet/be_ethtool.c b/drivers/net/benet/be_ethtool.c
index cda5bf2fc50a..f0fd95b43c07 100644
--- a/drivers/net/benet/be_ethtool.c
+++ b/drivers/net/benet/be_ethtool.c
@@ -323,10 +323,12 @@ be_set_pauseparam(struct net_device *netdev, struct ethtool_pauseparam *ecmd)
if (ecmd->autoneg != 0)
return -EINVAL;
+ adapter->tx_fc = ecmd->tx_pause;
+ adapter->rx_fc = ecmd->rx_pause;
- status = be_cmd_set_flow_control(adapter, ecmd->tx_pause,
- ecmd->rx_pause);
- if (!status)
+ status = be_cmd_set_flow_control(adapter,
+ adapter->tx_fc, adapter->rx_fc);
+ if (status)
dev_warn(&adapter->pdev->dev, "Pause param set failed.\n");
return status;
diff --git a/drivers/net/benet/be_main.c b/drivers/net/benet/be_main.c
index 1f941f027718..4a7a4527182d 100644
--- a/drivers/net/benet/be_main.c
+++ b/drivers/net/benet/be_main.c
@@ -1652,7 +1652,8 @@ static int be_setup(struct be_adapter *adapter)
if (status != 0)
goto mccqs_destroy;
- status = be_cmd_set_flow_control(adapter, true, true);
+ status = be_cmd_set_flow_control(adapter,
+ adapter->tx_fc, adapter->rx_fc);
if (status != 0)
goto mccqs_destroy;
return 0;
@@ -1909,6 +1910,10 @@ static void be_netdev_init(struct net_device *netdev)
adapter->rx_csum = true;
+ /* Default settings for Rx and Tx flow control */
+ adapter->rx_fc = true;
+ adapter->tx_fc = true;
+
netif_set_gso_max_size(netdev, 65535);
BE_SET_NETDEV_OPS(netdev, &be_netdev_ops);
@@ -2171,6 +2176,7 @@ static int be_suspend(struct pci_dev *pdev, pm_message_t state)
be_close(netdev);
rtnl_unlock();
}
+ be_cmd_get_flow_control(adapter, &adapter->tx_fc, &adapter->rx_fc);
be_clear(adapter);
pci_save_state(pdev);
OpenPOWER on IntegriCloud