summaryrefslogtreecommitdiffstats
path: root/drivers/md
diff options
context:
space:
mode:
authorNeilBrown <neilb@suse.de>2011-01-13 20:00:01 +0000
committerAlasdair G Kergon <agk@redhat.com>2011-01-13 20:00:01 +0000
commit9d357b0787bb3c91835d5e658c3bda178f9ca419 (patch)
tree48f2c3adc8ae06918ef0523f073291990407fa28 /drivers/md
parent4e2d19e46b507018c6ed15f6c081d8f887ae229c (diff)
downloadblackbird-op-linux-9d357b0787bb3c91835d5e658c3bda178f9ca419.tar.gz
blackbird-op-linux-9d357b0787bb3c91835d5e658c3bda178f9ca419.zip
dm: introduce target callbacks and congestion callback
DM currently implements congestion checking by checking on congestion in each component device. For raid456 we need to also check if the stripe cache is congested. Add per-target congestion checker callback support. Extending the target_callbacks structure with additional callback functions allows for establishing multiple callbacks per-target (a callback is also needed for unplug). Cc: linux-raid@vger.kernel.org Signed-off-by: NeilBrown <neilb@suse.de> Signed-off-by: Jonathan Brassow <jbrassow@redhat.com> Signed-off-by: Mike Snitzer <snitzer@redhat.com> Signed-off-by: Alasdair G Kergon <agk@redhat.com>
Diffstat (limited to 'drivers/md')
-rw-r--r--drivers/md/dm-table.c14
1 files changed, 14 insertions, 0 deletions
diff --git a/drivers/md/dm-table.c b/drivers/md/dm-table.c
index 985c20a4f30e..7e2ec3c05550 100644
--- a/drivers/md/dm-table.c
+++ b/drivers/md/dm-table.c
@@ -71,6 +71,8 @@ struct dm_table {
void *event_context;
struct dm_md_mempools *mempools;
+
+ struct list_head target_callbacks;
};
/*
@@ -204,6 +206,7 @@ int dm_table_create(struct dm_table **result, fmode_t mode,
return -ENOMEM;
INIT_LIST_HEAD(&t->devices);
+ INIT_LIST_HEAD(&t->target_callbacks);
atomic_set(&t->holders, 0);
t->discards_supported = 1;
@@ -1225,10 +1228,17 @@ int dm_table_resume_targets(struct dm_table *t)
return 0;
}
+void dm_table_add_target_callbacks(struct dm_table *t, struct dm_target_callbacks *cb)
+{
+ list_add(&cb->list, &t->target_callbacks);
+}
+EXPORT_SYMBOL_GPL(dm_table_add_target_callbacks);
+
int dm_table_any_congested(struct dm_table *t, int bdi_bits)
{
struct dm_dev_internal *dd;
struct list_head *devices = dm_table_get_devices(t);
+ struct dm_target_callbacks *cb;
int r = 0;
list_for_each_entry(dd, devices, list) {
@@ -1243,6 +1253,10 @@ int dm_table_any_congested(struct dm_table *t, int bdi_bits)
bdevname(dd->dm_dev.bdev, b));
}
+ list_for_each_entry(cb, &t->target_callbacks, list)
+ if (cb->congested_fn)
+ r |= cb->congested_fn(cb, bdi_bits);
+
return r;
}
OpenPOWER on IntegriCloud