summaryrefslogtreecommitdiffstats
path: root/drivers/i2c
diff options
context:
space:
mode:
authorEnrik Berkhan <Enrik.Berkhan@ge.com>2009-05-05 08:39:25 +0200
committerJean Delvare <khali@linux-fr.org>2009-05-05 08:39:25 +0200
commit2196d1cf4afab93fb64c2e5b417096e49b661612 (patch)
treeb9534b056eeb3a2e43620ef8ea52dd519ba50ba6 /drivers/i2c
parent0cdba07bb23cdd3e0d64357ec3d983e6b75e541f (diff)
downloadblackbird-op-linux-2196d1cf4afab93fb64c2e5b417096e49b661612.tar.gz
blackbird-op-linux-2196d1cf4afab93fb64c2e5b417096e49b661612.zip
i2c-algo-pca: Let PCA9564 recover from unacked data byte (state 0x30)
Currently, the i2c-algo-pca driver does nothing if the chip enters state 0x30 (Data byte in I2CDAT has been transmitted; NOT ACK has been received). Thus, the i2c bus connected to the controller gets stuck afterwards. I have seen this kind of error on a custom board in certain load situations most probably caused by interference or noise. A possible reaction is to let the controller generate a STOP condition. This is documented in the PCA9564 data sheet (2006-09-01) and the same is done for other NACK states as well. Further, state 0x38 isn't handled completely, either. Try to do another START in this case like the data sheet says. As this couldn't be tested, I've added a comment to try to reset the chip if the START doesn't help as suggested by Wolfram Sang. Signed-off-by: Enrik Berkhan <Enrik.Berkhan@ge.com> Reviewed-by: Wolfram Sang <w.sang@pengutronix.de> Signed-off-by: Jean Delvare <khali@linux-fr.org>
Diffstat (limited to 'drivers/i2c')
-rw-r--r--drivers/i2c/algos/i2c-algo-pca.c11
1 files changed, 11 insertions, 0 deletions
diff --git a/drivers/i2c/algos/i2c-algo-pca.c b/drivers/i2c/algos/i2c-algo-pca.c
index 6318f7ddc1d4..78d42aae0089 100644
--- a/drivers/i2c/algos/i2c-algo-pca.c
+++ b/drivers/i2c/algos/i2c-algo-pca.c
@@ -287,10 +287,21 @@ static int pca_xfer(struct i2c_adapter *i2c_adap,
case 0x30: /* Data byte in I2CDAT has been transmitted; NOT ACK has been received */
DEB2("NOT ACK received after data byte\n");
+ pca_stop(adap);
goto out;
case 0x38: /* Arbitration lost during SLA+W, SLA+R or data bytes */
DEB2("Arbitration lost\n");
+ /*
+ * The PCA9564 data sheet (2006-09-01) says "A
+ * START condition will be transmitted when the
+ * bus becomes free (STOP or SCL and SDA high)"
+ * when the STA bit is set (p. 11).
+ *
+ * In case this won't work, try pca_reset()
+ * instead.
+ */
+ pca_start(adap);
goto out;
case 0x58: /* Data byte has been received; NOT ACK has been returned */
OpenPOWER on IntegriCloud