summaryrefslogtreecommitdiffstats
path: root/drivers/i2c
diff options
context:
space:
mode:
authorChen-Yu Tsai <wens@csie.org>2014-09-01 22:28:13 +0800
committerWolfram Sang <wsa@the-dreams.de>2014-09-02 12:34:08 +0200
commit0ce4bc1dbdd911ae1763e2d4ff36bd1b214a59f7 (patch)
tree0e2c99c48bb50cbafa8c9e3d5641067a720fd24b /drivers/i2c
parentdd318b0df27c582ac0d72a346fd6e693700be23c (diff)
downloadblackbird-op-linux-0ce4bc1dbdd911ae1763e2d4ff36bd1b214a59f7.tar.gz
blackbird-op-linux-0ce4bc1dbdd911ae1763e2d4ff36bd1b214a59f7.zip
i2c: mv64xxx: continue probe when clock-frequency is missing
The "clock-frequency" DT property is listed as optional, However, the current code stores the return value of of_property_read_u32 in the return code of mv64xxx_of_config, but then forgets to clear it after setting the default value of "clock-frequency". It is then passed out to the main probe function, resulting in a probe failure when "clock-frequency" is missing. This patch checks and then throws away the return value of of_property_read_u32, instead of storing it and having to clear it afterwards. This issue was discovered after the property was removed from all sunxi DTs. Fixes: 4c730a06c19bb ("i2c: mv64xxx: Set bus frequency to 100kHz if clock-frequency is not provided") Signed-off-by: Chen-Yu Tsai <wens@csie.org> Cc: stable@vger.kernel.org Acked-by: Andrew Lunn <andrew@lunn.ch> Acked-by: Maxime Ripard <maxime.ripard@free-electrons.com> Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
Diffstat (limited to 'drivers/i2c')
-rw-r--r--drivers/i2c/busses/i2c-mv64xxx.c3
1 files changed, 1 insertions, 2 deletions
diff --git a/drivers/i2c/busses/i2c-mv64xxx.c b/drivers/i2c/busses/i2c-mv64xxx.c
index 6dc5ded86f62..2f64273d3f2b 100644
--- a/drivers/i2c/busses/i2c-mv64xxx.c
+++ b/drivers/i2c/busses/i2c-mv64xxx.c
@@ -746,8 +746,7 @@ mv64xxx_of_config(struct mv64xxx_i2c_data *drv_data,
}
tclk = clk_get_rate(drv_data->clk);
- rc = of_property_read_u32(np, "clock-frequency", &bus_freq);
- if (rc)
+ if (of_property_read_u32(np, "clock-frequency", &bus_freq))
bus_freq = 100000; /* 100kHz by default */
if (!mv64xxx_find_baud_factors(bus_freq, tclk,
OpenPOWER on IntegriCloud