summaryrefslogtreecommitdiffstats
path: root/drivers/char/agp/generic.c
diff options
context:
space:
mode:
authorDave Jones <davej@redhat.com>2006-11-03 15:13:27 -0500
committerDave Jones <davej@redhat.com>2006-11-03 15:13:27 -0500
commit28af24bb8470c7d0573b703a2955548b73a6c066 (patch)
treec8b68e60d8195e1200bf95cfdef0b3e5c53a28ed /drivers/char/agp/generic.c
parent18088748d2a493ce9f6adf0be7f833b04041807e (diff)
downloadblackbird-op-linux-28af24bb8470c7d0573b703a2955548b73a6c066.tar.gz
blackbird-op-linux-28af24bb8470c7d0573b703a2955548b73a6c066.zip
[AGPGART] Fix up misprogrammed bridges with incorrect AGPv2 rates.
Some dumb bridges are programmed to disobey the AGP2 spec. This is likely a BIOS misprogramming rather than poweron default, or it would be a lot more common. AGPv2 spec 6.1.9 states: "The RATE field indicates the data transfer rates supported by this device. A.G.P. devices must report all that apply." Fix them up as best we can. This will prevent errors like.. agpgart: Found an AGP 3.5 compliant device at 0000:00:00.0. agpgart: req mode 1f000201 bridge_agpstat 1f000a14 vga_agpstat 2f000217. agpgart: Device is in legacy mode, falling back to 2.x agpgart: Putting AGP V2 device at 0000:00:00.0 into 0x mode agpgart: Putting AGP V2 device at 0000:01:00.0 into 0x mode agpgart: Putting AGP V2 device at 0000:01:00.1 into 0x mode https://bugs.freedesktop.org/show_bug.cgi?id=8816 Signed-off-by: Dave Jones <davej@redhat.com>
Diffstat (limited to 'drivers/char/agp/generic.c')
-rw-r--r--drivers/char/agp/generic.c25
1 files changed, 25 insertions, 0 deletions
diff --git a/drivers/char/agp/generic.c b/drivers/char/agp/generic.c
index c39200161688..ca4629f66d17 100644
--- a/drivers/char/agp/generic.c
+++ b/drivers/char/agp/generic.c
@@ -419,6 +419,31 @@ static void agp_v2_parse_one(u32 *requested_mode, u32 *bridge_agpstat, u32 *vga_
*requested_mode &= ~AGP2_RESERVED_MASK;
}
+ /*
+ * Some dumb bridges are programmed to disobey the AGP2 spec.
+ * This is likely a BIOS misprogramming rather than poweron default, or
+ * it would be a lot more common.
+ * https://bugs.freedesktop.org/show_bug.cgi?id=8816
+ * AGPv2 spec 6.1.9 states:
+ * The RATE field indicates the data transfer rates supported by this
+ * device. A.G.P. devices must report all that apply.
+ * Fix them up as best we can.
+ */
+ switch (*bridge_agpstat & 7) {
+ case 4:
+ *bridge_agpstat |= (AGPSTAT2_2X | AGPSTAT2_1X);
+ printk(KERN_INFO PFX "BIOS bug. AGP bridge claims to only support x4 rate"
+ "Fixing up support for x2 & x1\n");
+ break;
+ case 2:
+ *bridge_agpstat |= AGPSTAT2_1X;
+ printk(KERN_INFO PFX "BIOS bug. AGP bridge claims to only support x2 rate"
+ "Fixing up support for x1\n");
+ break;
+ default:
+ break;
+ }
+
/* Check the speed bits make sense. Only one should be set. */
tmp = *requested_mode & 7;
switch (tmp) {
OpenPOWER on IntegriCloud