diff options
author | Konrad Rzeszutek Wilk <konrad.wilk@oracle.com> | 2013-11-26 15:05:40 -0500 |
---|---|---|
committer | Konrad Rzeszutek Wilk <konrad.wilk@oracle.com> | 2014-01-03 14:54:18 -0500 |
commit | 51c71a3bbaca868043cc45b3ad3786dd48a90235 (patch) | |
tree | 65cef69a3d3434393f1c063b8cf138d9a06e3154 /arch/x86/xen | |
parent | 802eee95bde72fd0cd0f3a5b2098375a487d1eda (diff) | |
download | blackbird-op-linux-51c71a3bbaca868043cc45b3ad3786dd48a90235.tar.gz blackbird-op-linux-51c71a3bbaca868043cc45b3ad3786dd48a90235.zip |
xen/pvhvm: If xen_platform_pci=0 is set don't blow up (v4).
The user has the option of disabling the platform driver:
00:02.0 Unassigned class [ff80]: XenSource, Inc. Xen Platform Device (rev 01)
which is used to unplug the emulated drivers (IDE, Realtek 8169, etc)
and allow the PV drivers to take over. If the user wishes
to disable that they can set:
xen_platform_pci=0
(in the guest config file)
or
xen_emul_unplug=never
(on the Linux command line)
except it does not work properly. The PV drivers still try to
load and since the Xen platform driver is not run - and it
has not initialized the grant tables, most of the PV drivers
stumble upon:
input: Xen Virtual Keyboard as /devices/virtual/input/input5
input: Xen Virtual Pointer as /devices/virtual/input/input6M
------------[ cut here ]------------
kernel BUG at /home/konrad/ssd/konrad/linux/drivers/xen/grant-table.c:1206!
invalid opcode: 0000 [#1] SMP
Modules linked in: xen_kbdfront(+) xenfs xen_privcmd
CPU: 6 PID: 1389 Comm: modprobe Not tainted 3.13.0-rc1upstream-00021-ga6c892b-dirty #1
Hardware name: Xen HVM domU, BIOS 4.4-unstable 11/26/2013
RIP: 0010:[<ffffffff813ddc40>] [<ffffffff813ddc40>] get_free_entries+0x2e0/0x300
Call Trace:
[<ffffffff8150d9a3>] ? evdev_connect+0x1e3/0x240
[<ffffffff813ddd0e>] gnttab_grant_foreign_access+0x2e/0x70
[<ffffffffa0010081>] xenkbd_connect_backend+0x41/0x290 [xen_kbdfront]
[<ffffffffa0010a12>] xenkbd_probe+0x2f2/0x324 [xen_kbdfront]
[<ffffffff813e5757>] xenbus_dev_probe+0x77/0x130
[<ffffffff813e7217>] xenbus_frontend_dev_probe+0x47/0x50
[<ffffffff8145e9a9>] driver_probe_device+0x89/0x230
[<ffffffff8145ebeb>] __driver_attach+0x9b/0xa0
[<ffffffff8145eb50>] ? driver_probe_device+0x230/0x230
[<ffffffff8145eb50>] ? driver_probe_device+0x230/0x230
[<ffffffff8145cf1c>] bus_for_each_dev+0x8c/0xb0
[<ffffffff8145e7d9>] driver_attach+0x19/0x20
[<ffffffff8145e260>] bus_add_driver+0x1a0/0x220
[<ffffffff8145f1ff>] driver_register+0x5f/0xf0
[<ffffffff813e55c5>] xenbus_register_driver_common+0x15/0x20
[<ffffffff813e76b3>] xenbus_register_frontend+0x23/0x40
[<ffffffffa0015000>] ? 0xffffffffa0014fff
[<ffffffffa001502b>] xenkbd_init+0x2b/0x1000 [xen_kbdfront]
[<ffffffff81002049>] do_one_initcall+0x49/0x170
.. snip..
which is hardly nice. This patch fixes this by having each
PV driver check for:
- if running in PV, then it is fine to execute (as that is their
native environment).
- if running in HVM, check if user wanted 'xen_emul_unplug=never',
in which case bail out and don't load any PV drivers.
- if running in HVM, and if PCI device 5853:0001 (xen_platform_pci)
does not exist, then bail out and not load PV drivers.
- (v2) if running in HVM, and if the user wanted 'xen_emul_unplug=ide-disks',
then bail out for all PV devices _except_ the block one.
Ditto for the network one ('nics').
- (v2) if running in HVM, and if the user wanted 'xen_emul_unplug=unnecessary'
then load block PV driver, and also setup the legacy IDE paths.
In (v3) make it actually load PV drivers.
Reported-by: Sander Eikelenboom <linux@eikelenboom.it
Reported-by: Anthony PERARD <anthony.perard@citrix.com>
Reported-and-Tested-by: Fabio Fantoni <fabio.fantoni@m2r.biz>
Signed-off-by: Konrad Rzeszutek Wilk <konrad.wilk@oracle.com>
[v2: Add extra logic to handle the myrid ways 'xen_emul_unplug'
can be used per Ian and Stefano suggestion]
[v3: Make the unnecessary case work properly]
[v4: s/disks/ide-disks/ spotted by Fabio]
Reviewed-by: Stefano Stabellini <stefano.stabellini@eu.citrix.com>
Acked-by: Bjorn Helgaas <bhelgaas@google.com> [for PCI parts]
CC: stable@vger.kernel.org
Diffstat (limited to 'arch/x86/xen')
-rw-r--r-- | arch/x86/xen/platform-pci-unplug.c | 74 |
1 files changed, 74 insertions, 0 deletions
diff --git a/arch/x86/xen/platform-pci-unplug.c b/arch/x86/xen/platform-pci-unplug.c index 0a7852483ffe..ab84ac198a9a 100644 --- a/arch/x86/xen/platform-pci-unplug.c +++ b/arch/x86/xen/platform-pci-unplug.c @@ -69,6 +69,80 @@ static int check_platform_magic(void) return 0; } +bool xen_has_pv_devices() +{ + if (!xen_domain()) + return false; + + /* PV domains always have them. */ + if (xen_pv_domain()) + return true; + + /* And user has xen_platform_pci=0 set in guest config as + * driver did not modify the value. */ + if (xen_platform_pci_unplug == 0) + return false; + + if (xen_platform_pci_unplug & XEN_UNPLUG_NEVER) + return false; + + if (xen_platform_pci_unplug & XEN_UNPLUG_ALL) + return true; + + /* This is an odd one - we are going to run legacy + * and PV drivers at the same time. */ + if (xen_platform_pci_unplug & XEN_UNPLUG_UNNECESSARY) + return true; + + /* And the caller has to follow with xen_pv_{disk,nic}_devices + * to be certain which driver can load. */ + return false; +} +EXPORT_SYMBOL_GPL(xen_has_pv_devices); + +static bool __xen_has_pv_device(int state) +{ + /* HVM domains might or might not */ + if (xen_hvm_domain() && (xen_platform_pci_unplug & state)) + return true; + + return xen_has_pv_devices(); +} + +bool xen_has_pv_nic_devices(void) +{ + return __xen_has_pv_device(XEN_UNPLUG_ALL_NICS | XEN_UNPLUG_ALL); +} +EXPORT_SYMBOL_GPL(xen_has_pv_nic_devices); + +bool xen_has_pv_disk_devices(void) +{ + return __xen_has_pv_device(XEN_UNPLUG_ALL_IDE_DISKS | + XEN_UNPLUG_AUX_IDE_DISKS | XEN_UNPLUG_ALL); +} +EXPORT_SYMBOL_GPL(xen_has_pv_disk_devices); + +/* + * This one is odd - it determines whether you want to run PV _and_ + * legacy (IDE) drivers together. This combination is only possible + * under HVM. + */ +bool xen_has_pv_and_legacy_disk_devices(void) +{ + if (!xen_domain()) + return false; + + /* N.B. This is only ever used in HVM mode */ + if (xen_pv_domain()) + return false; + + if (xen_platform_pci_unplug & XEN_UNPLUG_UNNECESSARY) + return true; + + return false; +} +EXPORT_SYMBOL_GPL(xen_has_pv_and_legacy_disk_devices); + void xen_unplug_emulated_devices(void) { int r; |