summaryrefslogtreecommitdiffstats
path: root/arch/powerpc
diff options
context:
space:
mode:
authorLinus Torvalds <torvalds@linux-foundation.org>2010-03-18 16:52:46 -0700
committerLinus Torvalds <torvalds@linux-foundation.org>2010-03-18 16:52:46 -0700
commitf82c37e7bb4c4d9b6a476c642d5c2d2efbd6f240 (patch)
tree09fc553c2fb6f527962048d139159dc139e04afc /arch/powerpc
parentc6b9e73f2fee8bb86058f296de808b326473456b (diff)
parentdcd5c1662db59a6b82942f47fb6ac9dd63f6d3dd (diff)
downloadblackbird-op-linux-f82c37e7bb4c4d9b6a476c642d5c2d2efbd6f240.tar.gz
blackbird-op-linux-f82c37e7bb4c4d9b6a476c642d5c2d2efbd6f240.zip
Merge branch 'perf-fixes-for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/tip/linux-2.6-tip
* 'perf-fixes-for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/tip/linux-2.6-tip: (35 commits) perf: Fix unexported generic perf_arch_fetch_caller_regs perf record: Don't try to find buildids in a zero sized file perf: export perf_trace_regs and perf_arch_fetch_caller_regs perf, x86: Fix hw_perf_enable() event assignment perf, ppc: Fix compile error due to new cpu notifiers perf: Make the install relative to DESTDIR if specified kprobes: Calculate the index correctly when freeing the out-of-line execution slot perf tools: Fix sparse CPU numbering related bugs perf_event: Fix oops triggered by cpu offline/online perf: Drop the obsolete profile naming for trace events perf: Take a hot regs snapshot for trace events perf: Introduce new perf_fetch_caller_regs() for hot regs snapshot perf/x86-64: Use frame pointer to walk on irq and process stacks lockdep: Move lock events under lockdep recursion protection perf report: Print the map table just after samples for which no map was found perf report: Add multiple event support perf session: Change perf_session post processing functions to take histogram tree perf session: Add storage for seperating event types in report perf session: Change add_hist_entry to take the tree root instead of session perf record: Add ID and to recorded event data when recording multiple events ...
Diffstat (limited to 'arch/powerpc')
-rw-r--r--arch/powerpc/kernel/perf_event.c21
1 files changed, 20 insertions, 1 deletions
diff --git a/arch/powerpc/kernel/perf_event.c b/arch/powerpc/kernel/perf_event.c
index 5120bd44f69a..08460a2e9f41 100644
--- a/arch/powerpc/kernel/perf_event.c
+++ b/arch/powerpc/kernel/perf_event.c
@@ -1287,7 +1287,7 @@ static void perf_event_interrupt(struct pt_regs *regs)
irq_exit();
}
-void hw_perf_event_setup(int cpu)
+static void power_pmu_setup(int cpu)
{
struct cpu_hw_events *cpuhw = &per_cpu(cpu_hw_events, cpu);
@@ -1297,6 +1297,23 @@ void hw_perf_event_setup(int cpu)
cpuhw->mmcr[0] = MMCR0_FC;
}
+static int __cpuinit
+power_pmu_notifier(struct notifier_block *self, unsigned long action, void *hcpu)
+{
+ unsigned int cpu = (long)hcpu;
+
+ switch (action & ~CPU_TASKS_FROZEN) {
+ case CPU_UP_PREPARE:
+ power_pmu_setup(cpu);
+ break;
+
+ default:
+ break;
+ }
+
+ return NOTIFY_OK;
+}
+
int register_power_pmu(struct power_pmu *pmu)
{
if (ppmu)
@@ -1314,5 +1331,7 @@ int register_power_pmu(struct power_pmu *pmu)
freeze_events_kernel = MMCR0_FCHV;
#endif /* CONFIG_PPC64 */
+ perf_cpu_notifier(power_pmu_notifier);
+
return 0;
}
OpenPOWER on IntegriCloud