Fix RGMII-ID handling in gianfar
The TSEC/eTSEC can detect the interface to the PHY automatically, but it isn't able to detect whether the RGMII connection needs internal delay. So we need to detect that change in the device tree, propagate it to the platform data, and then check it if we're in RGMII. This fixes a bug on the 8641D HPCN board where the Vitesse PHY doesn't use the delay for RGMII. Signed-off-by: Andy Fleming <afleming@freescale.com>
Diffstat (limited to 'arch/powerpc/sysdev/fsl_soc.c')
-rw-r--r--arch/powerpc/sysdev/fsl_soc.c9
1 files changed, 9 insertions, 0 deletions
diff --git a/arch/powerpc/sysdev/fsl_soc.c b/arch/powerpc/sysdev/fsl_soc.c
index c0ddc80d8160..3289fab01e92 100644
--- a/arch/powerpc/sysdev/fsl_soc.c
+++ b/arch/powerpc/sysdev/fsl_soc.c
@@ -197,6 +197,7 @@ static int __init gfar_of_init(void)
struct gianfar_platform_data gfar_data;
const unsigned int *id;
const char *model;
+ const char *ctype;
const void *mac_addr;
const phandle *ph;
int n_res = 2;
@@ -254,6 +255,14 @@ static int __init gfar_of_init(void)
FSL_GIANFAR_DEV_HAS_VLAN |
FSL_GIANFAR_DEV_HAS_EXTENDED_HASH;
+ ctype = of_get_property(np, "phy-connection-type", NULL);
+
+ /* We only care about rgmii-id. The rest are autodetected */
+ if (ctype && !strcmp(ctype, "rgmii-id"))
+ gfar_data.interface = PHY_INTERFACE_MODE_RGMII_ID;
+ else
+ gfar_data.interface = PHY_INTERFACE_MODE_MII;
+
ph = of_get_property(np, "phy-handle", NULL);
phy = of_find_node_by_phandle(*ph);