summaryrefslogtreecommitdiffstats
path: root/arch/powerpc/kernel/pci_64.c
diff options
context:
space:
mode:
authorPaul Mackerras <paulus@samba.org>2008-12-28 14:12:57 +0000
committerBenjamin Herrenschmidt <benh@kernel.crashing.org>2009-01-08 16:25:11 +1100
commit16124f10df43e6e08783f1fede6888bf36ac705c (patch)
treee968c899a9dffaf7d10a8c698ae54d3259e56d71 /arch/powerpc/kernel/pci_64.c
parent1d5bc03a8183d12c7daf4e7c69cce8d9c4b9a86b (diff)
downloadblackbird-op-linux-16124f10df43e6e08783f1fede6888bf36ac705c.tar.gz
blackbird-op-linux-16124f10df43e6e08783f1fede6888bf36ac705c.zip
powerpc: Fix pciconfig_iobase system call on PCI-Express powermac
X has been failing to start on my quad G5 powermac since commit 1fd0f52583a85b21a394201b007bc1ee104b235d ("powerpc: Fix domain numbers in /proc on 64-bit") went in. The reason is that the change allows X to see the PCI-PCI bridge above the video card (previously it was obscured by the fact that there were two "00" directories in /proc/bus/pci), and the pciconfig_iobase system call on the bridge is failing because of a hack that we have to return information about the AGP bus when X asks about bus 0. This machine doesn't have an AGP bus (it has PCI Express) and so the pciconfig_iobase call is returning -1, which ultimately causes X to fail to start. This fixes it by checking that we have an AGP bridge before redirecting the pciconfig_iobase call to return information about the AGP bus. With this, X starts successfully both on a quad G5 with PCI Express and on an older dual G5 with AGP. Signed-off-by: Paul Mackerras <paulus@samba.org> Acked-by: Benjamin Herrenschmidt <benh@kernel.crashing.org> Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org>
Diffstat (limited to 'arch/powerpc/kernel/pci_64.c')
-rw-r--r--arch/powerpc/kernel/pci_64.c9
1 files changed, 7 insertions, 2 deletions
diff --git a/arch/powerpc/kernel/pci_64.c b/arch/powerpc/kernel/pci_64.c
index 39fadc6e1492..586962f65c2a 100644
--- a/arch/powerpc/kernel/pci_64.c
+++ b/arch/powerpc/kernel/pci_64.c
@@ -560,9 +560,14 @@ long sys_pciconfig_iobase(long which, unsigned long in_bus,
* G5 machines... So when something asks for bus 0 io base
* (bus 0 is HT root), we return the AGP one instead.
*/
- if (machine_is_compatible("MacRISC4"))
- if (in_bus == 0)
+ if (in_bus == 0 && machine_is_compatible("MacRISC4")) {
+ struct device_node *agp;
+
+ agp = of_find_compatible_node(NULL, NULL, "u3-agp");
+ if (agp)
in_bus = 0xf0;
+ of_node_put(agp);
+ }
/* That syscall isn't quite compatible with PCI domains, but it's
* used on pre-domains setup. We return the first match
OpenPOWER on IntegriCloud