summaryrefslogtreecommitdiffstats
path: root/Documentation
diff options
context:
space:
mode:
authorLinus Torvalds <torvalds@linux-foundation.org>2012-10-13 11:27:59 +0900
committerLinus Torvalds <torvalds@linux-foundation.org>2012-10-13 11:27:59 +0900
commita3920a6efa158b445b8a39080b463b9b29337425 (patch)
tree1726a21d317bea8039c1f0f041b7443af76f6ca1 /Documentation
parent18a022de47bc11ee20d7d0f4dd72d42d2cfdc51c (diff)
parentd1d4a81b842db21b144ffd2334ca5eee3eb740f3 (diff)
downloadblackbird-op-linux-a3920a6efa158b445b8a39080b463b9b29337425.tar.gz
blackbird-op-linux-a3920a6efa158b445b8a39080b463b9b29337425.zip
Merge branch 'release' of git://git.kernel.org/pub/scm/linux/kernel/git/lenb/linux
Pull ACPI & Thermal updates from Len Brown: "The generic Linux thermal layer is gaining some new capabilities (generic cooling via cpufreq) and some new customers (ARM). Also, an ACPI EC bug fix plus a regression fix." * 'release' of git://git.kernel.org/pub/scm/linux/kernel/git/lenb/linux: (30 commits) tools/power/acpi/acpidump: remove duplicated include from acpidump.c ACPI idle, CPU hotplug: Fix NULL pointer dereference during hotplug cpuidle / ACPI: fix potential NULL pointer dereference ACPI: EC: Add a quirk for CLEVO M720T/M730T laptop ACPI: EC: Make the GPE storm threshold a module parameter thermal: Exynos: Fix NULL pointer dereference in exynos_unregister_thermal() Thermal: Fix bug on cpu_cooling, cooling device's id conflict problem. thermal: exynos: Use devm_* functions ARM: exynos: add thermal sensor driver platform data support thermal: exynos: register the tmu sensor with the kernel thermal layer thermal: exynos5: add exynos5250 thermal sensor driver support hwmon: exynos4: move thermal sensor driver to driver/thermal directory thermal: add generic cpufreq cooling implementation Fix a build error. thermal: Fix potential NULL pointer accesses thermal: add Renesas R-Car thermal sensor support thermal: fix potential out-of-bounds memory access Thermal: Introduce locking for cdev.thermal_instances list. Thermal: Unify the code for both active and passive cooling Thermal: Introduce simple arbitrator for setting device cooling state ...
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/thermal/cpu-cooling-api.txt32
-rw-r--r--Documentation/thermal/exynos_thermal (renamed from Documentation/hwmon/exynos4_tmu)35
-rw-r--r--Documentation/thermal/sysfs-api.txt9
3 files changed, 43 insertions, 33 deletions
diff --git a/Documentation/thermal/cpu-cooling-api.txt b/Documentation/thermal/cpu-cooling-api.txt
new file mode 100644
index 000000000000..fca24c931ec8
--- /dev/null
+++ b/Documentation/thermal/cpu-cooling-api.txt
@@ -0,0 +1,32 @@
+CPU cooling APIs How To
+===================================
+
+Written by Amit Daniel Kachhap <amit.kachhap@linaro.org>
+
+Updated: 12 May 2012
+
+Copyright (c) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com)
+
+0. Introduction
+
+The generic cpu cooling(freq clipping) provides registration/unregistration APIs
+to the caller. The binding of the cooling devices to the trip point is left for
+the user. The registration APIs returns the cooling device pointer.
+
+1. cpu cooling APIs
+
+1.1 cpufreq registration/unregistration APIs
+1.1.1 struct thermal_cooling_device *cpufreq_cooling_register(
+ struct cpumask *clip_cpus)
+
+ This interface function registers the cpufreq cooling device with the name
+ "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
+ cooling devices.
+
+ clip_cpus: cpumask of cpus where the frequency constraints will happen.
+
+1.1.2 void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
+
+ This interface function unregisters the "thermal-cpufreq-%x" cooling device.
+
+ cdev: Cooling device pointer which has to be unregistered.
diff --git a/Documentation/hwmon/exynos4_tmu b/Documentation/thermal/exynos_thermal
index c3c6b41db607..2b46f67b1ccb 100644
--- a/Documentation/hwmon/exynos4_tmu
+++ b/Documentation/thermal/exynos_thermal
@@ -46,36 +46,7 @@ The threshold levels are defined as follows:
The threshold and each trigger_level are set
through the corresponding registers.
-When an interrupt occurs, this driver notify user space of
-one of four threshold levels for the interrupt
-through kobject_uevent_env and sysfs_notify functions.
+When an interrupt occurs, this driver notify kernel thermal framework
+with the function exynos4_report_trigger.
Although an interrupt condition for level_0 can be set,
-it is not notified to user space through sysfs_notify function.
-
-Sysfs Interface
----------------
-name name of the temperature sensor
- RO
-
-temp1_input temperature
- RO
-
-temp1_max temperature for level_1 interrupt
- RO
-
-temp1_crit temperature for level_2 interrupt
- RO
-
-temp1_emergency temperature for level_3 interrupt
- RO
-
-temp1_max_alarm alarm for level_1 interrupt
- RO
-
-temp1_crit_alarm
- alarm for level_2 interrupt
- RO
-
-temp1_emergency_alarm
- alarm for level_3 interrupt
- RO
+it can be used to synchronize the cooling action.
diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt
index c087dbcf3535..ca1a1a34970e 100644
--- a/Documentation/thermal/sysfs-api.txt
+++ b/Documentation/thermal/sysfs-api.txt
@@ -84,7 +84,8 @@ temperature) and throttle appropriate devices.
1.3 interface for binding a thermal zone device with a thermal cooling device
1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
- int trip, struct thermal_cooling_device *cdev);
+ int trip, struct thermal_cooling_device *cdev,
+ unsigned long upper, unsigned long lower);
This interface function bind a thermal cooling device to the certain trip
point of a thermal zone device.
@@ -93,6 +94,12 @@ temperature) and throttle appropriate devices.
cdev: thermal cooling device
trip: indicates which trip point the cooling devices is associated with
in this thermal zone.
+ upper:the Maximum cooling state for this trip point.
+ THERMAL_NO_LIMIT means no upper limit,
+ and the cooling device can be in max_state.
+ lower:the Minimum cooling state can be used for this trip point.
+ THERMAL_NO_LIMIT means no lower limit,
+ and the cooling device can be in cooling state 0.
1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
int trip, struct thermal_cooling_device *cdev);
OpenPOWER on IntegriCloud