summaryrefslogtreecommitdiffstats
path: root/Documentation
diff options
context:
space:
mode:
authorGuenter Roeck <guenter.roeck@ericsson.com>2011-04-18 09:48:58 -0700
committerGuenter Roeck <guenter.roeck@ericsson.com>2011-04-19 08:49:57 -0700
commit180b3d889c85ce25d080997cc0c6cee4e46eed54 (patch)
treeada63492124ea0bc47f5a54b3be4d169aa659a86 /Documentation
parentc1a76b47419ebb143559feaedfb35e4f285095b9 (diff)
downloadblackbird-op-linux-180b3d889c85ce25d080997cc0c6cee4e46eed54.tar.gz
blackbird-op-linux-180b3d889c85ce25d080997cc0c6cee4e46eed54.zip
hwmon: (pmbus) Documentation updates
Fix spelling, correct label name error, and add missing attribute to PMBus driver documentation. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Tom Grennan <tom.grennan@ericsson.com>
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/hwmon/pmbus14
1 files changed, 8 insertions, 6 deletions
diff --git a/Documentation/hwmon/pmbus b/Documentation/hwmon/pmbus
index dc4933e96344..852d9ebcef3a 100644
--- a/Documentation/hwmon/pmbus
+++ b/Documentation/hwmon/pmbus
@@ -175,11 +175,13 @@ currX_crit Critical maximum current.
From IIN_OC_FAULT_LIMIT or IOUT_OC_FAULT_LIMIT register.
currX_alarm Current high alarm.
From IIN_OC_WARNING or IOUT_OC_WARNING status.
+currX_max_alarm Current high alarm.
+ From IIN_OC_WARN_LIMIT or IOUT_OC_WARN_LIMIT status.
currX_lcrit_alarm Output current critical low alarm.
From IOUT_UC_FAULT status.
currX_crit_alarm Current critical high alarm.
From IIN_OC_FAULT or IOUT_OC_FAULT status.
-currX_label "iin" or "vinY"
+currX_label "iin" or "ioutY"
powerX_input Measured power. From READ_PIN or READ_POUT register.
powerX_cap Output power cap. From POUT_MAX register.
@@ -193,13 +195,13 @@ powerX_crit_alarm Output power critical high alarm.
From POUT_OP_FAULT status.
powerX_label "pin" or "poutY"
-tempX_input Measured tempererature.
+tempX_input Measured temperature.
From READ_TEMPERATURE_X register.
-tempX_min Mimimum tempererature. From UT_WARN_LIMIT register.
-tempX_max Maximum tempererature. From OT_WARN_LIMIT register.
-tempX_lcrit Critical low tempererature.
+tempX_min Mimimum temperature. From UT_WARN_LIMIT register.
+tempX_max Maximum temperature. From OT_WARN_LIMIT register.
+tempX_lcrit Critical low temperature.
From UT_FAULT_LIMIT register.
-tempX_crit Critical high tempererature.
+tempX_crit Critical high temperature.
From OT_FAULT_LIMIT register.
tempX_min_alarm Chip temperature low alarm. Set by comparing
READ_TEMPERATURE_X with UT_WARN_LIMIT if
OpenPOWER on IntegriCloud