hwmon: Driver for TI TMP102 temperature sensor
Driver for the TI TMP102. The TI TMP102 is similar to the LM75. It differs from the LM75 by having a 16-bit conf register and the temp registers have a minimum resolution of 12 bits; the extended conf register can select 13-bit resolution (which this driver does) and also change the update rate (which this driver currently doesn't use). [JD: Fix tmp102_exit tag, must be __exit, not __init.] Signed-off-by: Steven King <sfking@fdwdc.com> Signed-off-by: Jean Delvare <khali@linux-fr.org>
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/hwmon/tmp10227
1 files changed, 27 insertions, 0 deletions
diff --git a/Documentation/hwmon/tmp102 b/Documentation/hwmon/tmp102
new file mode 100644
index 000000000000..239dded8539f
--- /dev/null
+++ b/Documentation/hwmon/tmp102
@@ -0,0 +1,27 @@
+Kernel driver tmp102
+====================
+
+Supported chips:
+ * Texas Instruments TMP102
+ Prefix: 'tmp102'
+ Addresses scanned: I2C 0x48 0x49 0x4a 0x4b
+ Datasheet: http://focus.ti.com/docs/prod/folders/print/tmp102.html
+
+Author:
+ Steven King <sfking@fdwdc.com>
+
+Description
+-----------
+
+The Texas Instruments TMP102 implements one temperature sensor. Limits can be
+set through the Overtemperature Shutdown register and Hysteresis register. The
+sensor is accurate to 0.5 degrees over the range of -25 to +85 C, and to 1.0
+degrees from -40 to +125 C. Resolution of the sensor is 0.0625 degree. The
+operating temperature has a minimum of -55 C and a maximum of +150 C.
+
+The TMP102 has a programmable update rate that can select between 8, 4, 1, and
+0.5 Hz. (Currently the driver only supports the default of 4 Hz).
+
+The driver provides the common sysfs-interface for temperatures (see
+/Documentation/hwmon/sysfs-interface under Temperatures).
+