diff options
author | stigge@antcom.de <stigge@antcom.de> | 2011-01-20 18:42:55 +0100 |
---|---|---|
committer | Guenter Roeck <guenter.roeck@ericsson.com> | 2011-03-14 22:36:24 -0700 |
commit | a5b79d62f2e6d1b0d44bcdafce46f47bf355b9fe (patch) | |
tree | dc918d8203b45d5dd4cd98e82ebd5f30bad0c94b /Documentation/hwmon | |
parent | 521cb40b0c44418a4fd36dc633f575813d59a43d (diff) | |
download | blackbird-op-linux-a5b79d62f2e6d1b0d44bcdafce46f47bf355b9fe.tar.gz blackbird-op-linux-a5b79d62f2e6d1b0d44bcdafce46f47bf355b9fe.zip |
hwmon: Driver for Maxim MAX6639
2-Channel Temperature Monitor with Dual PWM Fan-Speed Controller
Signed-off-by: Roland Stigge <stigge@antcom.de>
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r-- | Documentation/hwmon/max6639 | 49 |
1 files changed, 49 insertions, 0 deletions
diff --git a/Documentation/hwmon/max6639 b/Documentation/hwmon/max6639 new file mode 100644 index 000000000000..dc49f8be7167 --- /dev/null +++ b/Documentation/hwmon/max6639 @@ -0,0 +1,49 @@ +Kernel driver max6639 +===================== + +Supported chips: + * Maxim MAX6639 + Prefix: 'max6639' + Addresses scanned: I2C 0x2c, 0x2e, 0x2f + Datasheet: http://pdfserv.maxim-ic.com/en/ds/MAX6639.pdf + +Authors: + He Changqing <hechangqing@semptian.com> + Roland Stigge <stigge@antcom.de> + +Description +----------- + +This driver implements support for the Maxim MAX6639. This chip is a 2-channel +temperature monitor with dual PWM fan speed controller. It can monitor its own +temperature and one external diode-connected transistor or two external +diode-connected transistors. + +The following device attributes are implemented via sysfs: + +Attribute R/W Contents +---------------------------------------------------------------------------- +temp1_input R Temperature channel 1 input (0..150 C) +temp2_input R Temperature channel 2 input (0..150 C) +temp1_fault R Temperature channel 1 diode fault +temp2_fault R Temperature channel 2 diode fault +temp1_max RW Set THERM temperature for input 1 + (in C, see datasheet) +temp2_max RW Set THERM temperature for input 2 +temp1_crit RW Set ALERT temperature for input 1 +temp2_crit RW Set ALERT temperature for input 2 +temp1_emergency RW Set OT temperature for input 1 + (in C, see datasheet) +temp2_emergency RW Set OT temperature for input 2 +pwm1 RW Fan 1 target duty cycle (0..255) +pwm2 RW Fan 2 target duty cycle (0..255) +fan1_input R TACH1 fan tachometer input (in RPM) +fan2_input R TACH2 fan tachometer input (in RPM) +fan1_fault R Fan 1 fault +fan2_fault R Fan 2 fault +temp1_max_alarm R Alarm on THERM temperature on channel 1 +temp2_max_alarm R Alarm on THERM temperature on channel 2 +temp1_crit_alarm R Alarm on ALERT temperature on channel 1 +temp2_crit_alarm R Alarm on ALERT temperature on channel 2 +temp1_emergency_alarm R Alarm on OT temperature on channel 1 +temp2_emergency_alarm R Alarm on OT temperature on channel 2 |