authorJean Delvare <khali@linux-fr.org>2007-02-14 21:15:02 +0100
committerJean Delvare <khali@arrakis.delvare>2007-02-14 21:15:02 +0100
commitf8d0c19a93cea3a26a90f2462295e1e01a4cd250 (patch)
tree6d874a35f611a1c344896ef13a911a80a3d10017 /Documentation/hwmon/it87
parentac98695d6c1508b724f246f38ce57fb4e3cec356 (diff)
downloadblackbird-op-linux-f8d0c19a93cea3a26a90f2462295e1e01a4cd250.tar.gz
blackbird-op-linux-f8d0c19a93cea3a26a90f2462295e1e01a4cd250.zip
hwmon/it87: Add PWM base frequency control
Let the user select the base PWM frequency when using the it87 hardware monitoring driver. Different frequencies can give better control on some fans. Also update the documentation to mention the PWM frequency control files, with misc cleanups to the PWM section. Signed-off-by: Jean Delvare <khali@linux-fr.org>
Diffstat (limited to 'Documentation/hwmon/it87')
-rw-r--r--Documentation/hwmon/it8710
1 files changed, 10 insertions, 0 deletions
diff --git a/Documentation/hwmon/it87 b/Documentation/hwmon/it87
index 74a80992d237..c0528d6f9ace 100644
--- a/Documentation/hwmon/it87
+++ b/Documentation/hwmon/it87
@@ -135,6 +135,16 @@ Give 0 for unused sensor. Any other value is invalid. To configure this at
startup, consult lm_sensors's /etc/sensors.conf. (2 = thermistor;
3 = thermal diode)
+
+Fan speed control
+-----------------
+
The fan speed control features are limited to manual PWM mode. Automatic
"Smart Guardian" mode control handling is not implemented. However
if you want to go for "manual mode" just write 1 to pwmN_enable.
+
+If you are only able to control the fan speed with very small PWM values,
+try lowering the PWM base frequency (pwm1_freq). Depending on the fan,
+it may give you a somewhat greater control range. The same frequency is
+used to drive all fan outputs, which is why pwm2_freq and pwm3_freq are
+read-only.