summaryrefslogtreecommitdiffstats
path: root/Documentation/devicetree/bindings/pwm/pwm-tiecap.txt
diff options
context:
space:
mode:
authorLaurent Pinchart <laurent.pinchart+renesas@ideasonboard.com>2013-07-18 00:54:23 +0200
committerThierry Reding <thierry.reding@gmail.com>2013-09-03 13:08:10 +0200
commitebeec0af5b29635b847f5a7a17de1900193d0257 (patch)
tree0fe4464200d61b3fd7c25f9a9ac960adc40a4184 /Documentation/devicetree/bindings/pwm/pwm-tiecap.txt
parent208be7698fe39d54242348aef375fd86180c4506 (diff)
downloadblackbird-op-linux-ebeec0af5b29635b847f5a7a17de1900193d0257.tar.gz
blackbird-op-linux-ebeec0af5b29635b847f5a7a17de1900193d0257.zip
pwm: Update DT bindings to reference pwm.txt for cells documentation
The PWM client cells format is documented in the generic pwm.txt documentation and duplicated in all PWM driver bindings. Remove duplicate information and reference pwm.txt instead. Signed-off-by: Laurent Pinchart <laurent.pinchart+renesas@ideasonboard.com> Reviewed-by: Stephen Warren <swarren@nvidia.com> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
Diffstat (limited to 'Documentation/devicetree/bindings/pwm/pwm-tiecap.txt')
-rw-r--r--Documentation/devicetree/bindings/pwm/pwm-tiecap.txt8
1 files changed, 3 insertions, 5 deletions
diff --git a/Documentation/devicetree/bindings/pwm/pwm-tiecap.txt b/Documentation/devicetree/bindings/pwm/pwm-tiecap.txt
index 681afad73778..fb81179dce37 100644
--- a/Documentation/devicetree/bindings/pwm/pwm-tiecap.txt
+++ b/Documentation/devicetree/bindings/pwm/pwm-tiecap.txt
@@ -4,11 +4,9 @@ Required properties:
- compatible: Must be "ti,<soc>-ecap".
for am33xx - compatible = "ti,am33xx-ecap";
for da850 - compatible = "ti,da850-ecap", "ti,am33xx-ecap";
-- #pwm-cells: Should be 3. Number of cells being used to specify PWM property.
- First cell specifies the per-chip index of the PWM to use, the second
- cell is the period in nanoseconds and bit 0 in the third cell is used to
- encode the polarity of PWM output. Set bit 0 of the third in PWM specifier
- to 1 for inverse polarity & set to 0 for normal polarity.
+- #pwm-cells: should be 3. See pwm.txt in this directory for a description of
+ the cells format. The PWM channel index ranges from 0 to 4. The only third
+ cell flag supported by this binding is PWM_POLARITY_INVERTED.
- reg: physical base address and size of the registers map.
Optional properties:
OpenPOWER on IntegriCloud