summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorAuke Kok <auke-jan.h.kok@intel.com>2006-06-27 09:06:32 -0700
committerAuke Kok <juke-jan.h.kok@intel.com>2006-06-27 09:06:32 -0700
commit79f05bf0ba9b41561600f3cdfdf86b5184fc6675 (patch)
tree74530615703e52b238ec38c2fac2670a2493113e
parent2db10a081c5c1082d58809a1bcf1a6073f4db160 (diff)
downloadblackbird-op-linux-79f05bf0ba9b41561600f3cdfdf86b5184fc6675.tar.gz
blackbird-op-linux-79f05bf0ba9b41561600f3cdfdf86b5184fc6675.zip
e1000: Make PHY powerup/down a function
In relation to the irq work done earlier we also move the PHY powerup and powerdown functions into separate functions and move the calls to _close and _open, making the PHY stay in it's power state as long as the device is _up. Signed-off-by: Jesse Brandeburg <jesse.brandeburg@intel.com> Signed-off-by: Auke Kok <auke-jan.h.kok@intel.com>
-rw-r--r--drivers/net/e1000/e1000_main.c76
1 files changed, 49 insertions, 27 deletions
diff --git a/drivers/net/e1000/e1000_main.c b/drivers/net/e1000/e1000_main.c
index 52d698bb2595..813d5e0e458d 100644
--- a/drivers/net/e1000/e1000_main.c
+++ b/drivers/net/e1000/e1000_main.c
@@ -428,14 +428,6 @@ e1000_up(struct e1000_adapter *adapter)
/* hardware has been reset, we need to reload some things */
- /* Reset the PHY if it was previously powered down */
- if (adapter->hw.media_type == e1000_media_type_copper) {
- uint16_t mii_reg;
- e1000_read_phy_reg(&adapter->hw, PHY_CTRL, &mii_reg);
- if (mii_reg & MII_CR_POWER_DOWN)
- e1000_phy_hw_reset(&adapter->hw);
- }
-
e1000_set_multi(netdev);
e1000_restore_vlan(adapter);
@@ -464,12 +456,56 @@ e1000_up(struct e1000_adapter *adapter)
return 0;
}
+/**
+ * e1000_power_up_phy - restore link in case the phy was powered down
+ * @adapter: address of board private structure
+ *
+ * The phy may be powered down to save power and turn off link when the
+ * driver is unloaded and wake on lan is not enabled (among others)
+ * *** this routine MUST be followed by a call to e1000_reset ***
+ *
+ **/
+
+static void e1000_power_up_phy(struct e1000_adapter *adapter)
+{
+ uint16_t mii_reg = 0;
+
+ /* Just clear the power down bit to wake the phy back up */
+ if (adapter->hw.media_type == e1000_media_type_copper) {
+ /* according to the manual, the phy will retain its
+ * settings across a power-down/up cycle */
+ e1000_read_phy_reg(&adapter->hw, PHY_CTRL, &mii_reg);
+ mii_reg &= ~MII_CR_POWER_DOWN;
+ e1000_write_phy_reg(&adapter->hw, PHY_CTRL, mii_reg);
+ }
+}
+
+static void e1000_power_down_phy(struct e1000_adapter *adapter)
+{
+ boolean_t mng_mode_enabled = (adapter->hw.mac_type >= e1000_82571) &&
+ e1000_check_mng_mode(&adapter->hw);
+ /* Power down the PHY so no link is implied when interface is down
+ * The PHY cannot be powered down if any of the following is TRUE
+ * (a) WoL is enabled
+ * (b) AMT is active
+ * (c) SoL/IDER session is active */
+ if (!adapter->wol && adapter->hw.mac_type >= e1000_82540 &&
+ adapter->hw.media_type == e1000_media_type_copper &&
+ !(E1000_READ_REG(&adapter->hw, MANC) & E1000_MANC_SMBUS_EN) &&
+ !mng_mode_enabled &&
+ !e1000_check_phy_reset_block(&adapter->hw)) {
+ uint16_t mii_reg = 0;
+ e1000_read_phy_reg(&adapter->hw, PHY_CTRL, &mii_reg);
+ mii_reg |= MII_CR_POWER_DOWN;
+ e1000_write_phy_reg(&adapter->hw, PHY_CTRL, mii_reg);
+ mdelay(1);
+ }
+}
+
void
e1000_down(struct e1000_adapter *adapter)
{
struct net_device *netdev = adapter->netdev;
- boolean_t mng_mode_enabled = (adapter->hw.mac_type >= e1000_82571) &&
- e1000_check_mng_mode(&adapter->hw);
e1000_irq_disable(adapter);
@@ -489,23 +525,6 @@ e1000_down(struct e1000_adapter *adapter)
e1000_reset(adapter);
e1000_clean_all_tx_rings(adapter);
e1000_clean_all_rx_rings(adapter);
-
- /* Power down the PHY so no link is implied when interface is down *
- * The PHY cannot be powered down if any of the following is TRUE *
- * (a) WoL is enabled
- * (b) AMT is active
- * (c) SoL/IDER session is active */
- if (!adapter->wol && adapter->hw.mac_type >= e1000_82540 &&
- adapter->hw.media_type == e1000_media_type_copper &&
- !(E1000_READ_REG(&adapter->hw, MANC) & E1000_MANC_SMBUS_EN) &&
- !mng_mode_enabled &&
- !e1000_check_phy_reset_block(&adapter->hw)) {
- uint16_t mii_reg;
- e1000_read_phy_reg(&adapter->hw, PHY_CTRL, &mii_reg);
- mii_reg |= MII_CR_POWER_DOWN;
- e1000_write_phy_reg(&adapter->hw, PHY_CTRL, mii_reg);
- mdelay(1);
- }
}
void
@@ -1117,6 +1136,8 @@ e1000_open(struct net_device *netdev)
if (err)
goto err_up;
+ e1000_power_up_phy(adapter);
+
if ((err = e1000_up(adapter)))
goto err_up;
adapter->mng_vlan_id = E1000_MNG_VLAN_NONE;
@@ -1162,6 +1183,7 @@ e1000_close(struct net_device *netdev)
WARN_ON(test_bit(__E1000_RESETTING, &adapter->flags));
e1000_down(adapter);
+ e1000_power_down_phy(adapter);
e1000_free_irq(adapter);
e1000_free_all_tx_resources(adapter);
OpenPOWER on IntegriCloud