md: md: raid5 rate limit error printk
Last night we had scsi problems and a hardware raid unit was offlined during heavy i/o. While this happened we got for about 3 minutes a huge number messages like these Apr 12 03:36:07 pfs1n14 kernel: [197510.696595] raid5:md7: read error not correctable (sector 2993096568 on sdj2). I guess the high error rate is responsible for not scheduling other events - during this time the system was not pingable and in the end also other devices run into scsi command timeouts causing problems on these unrelated devices as well. Signed-off-by: Bernd Schubert <bernd-schubert@gmx.de> Signed-off-by: Dan Williams <dan.j.williams@intel.com> Signed-off-by: Neil Brown <neilb@suse.de> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
-rw-r--r--drivers/md/raid5.c34
1 files changed, 22 insertions, 12 deletions
diff --git a/drivers/md/raid5.c b/drivers/md/raid5.c
index 93fde48c0f42..2f28745dacf9 100644
--- a/drivers/md/raid5.c
+++ b/drivers/md/raid5.c
@@ -94,6 +94,8 @@
#define __inline__
#endif
+#define printk_rl(args...) ((void) (printk_ratelimit() && printk(args)))
+
#if !RAID6_USE_EMPTY_ZERO_PAGE
/* In .bss so it's zeroed */
const char raid6_empty_zero_page[PAGE_SIZE] __attribute__((aligned(256)));
@@ -1143,10 +1145,12 @@ static void raid5_end_read_request(struct bio * bi, int error)
set_bit(R5_UPTODATE, &sh->dev[i].flags);
if (test_bit(R5_ReadError, &sh->dev[i].flags)) {
rdev = conf->disks[i].rdev;
- printk(KERN_INFO "raid5:%s: read error corrected (%lu sectors at %llu on %s)\n",
- mdname(conf->mddev), STRIPE_SECTORS,
- (unsigned long long)(sh->sector + rdev->data_offset),
- bdevname(rdev->bdev, b));
+ printk_rl(KERN_INFO "raid5:%s: read error corrected"
+ " (%lu sectors at %llu on %s)\n",
+ mdname(conf->mddev), STRIPE_SECTORS,
+ (unsigned long long)(sh->sector
+ + rdev->data_offset),
+ bdevname(rdev->bdev, b));
clear_bit(R5_ReadError, &sh->dev[i].flags);
clear_bit(R5_ReWrite, &sh->dev[i].flags);
}
@@ -1160,16 +1164,22 @@ static void raid5_end_read_request(struct bio * bi, int error)
clear_bit(R5_UPTODATE, &sh->dev[i].flags);
atomic_inc(&rdev->read_errors);
if (conf->mddev->degraded)
- printk(KERN_WARNING "raid5:%s: read error not correctable (sector %llu on %s).\n",
- mdname(conf->mddev),
- (unsigned long long)(sh->sector + rdev->data_offset),
- bdn);
+ printk_rl(KERN_WARNING
+ "raid5:%s: read error not correctable "
+ "(sector %llu on %s).\n",
+ mdname(conf->mddev),
+ (unsigned long long)(sh->sector
+ + rdev->data_offset),
+ bdn);
else if (test_bit(R5_ReWrite, &sh->dev[i].flags))
/* Oh, no!!! */
- printk(KERN_WARNING "raid5:%s: read error NOT corrected!! (sector %llu on %s).\n",
- mdname(conf->mddev),
- (unsigned long long)(sh->sector + rdev->data_offset),
- bdn);
+ printk_rl(KERN_WARNING
+ "raid5:%s: read error NOT corrected!! "
+ "(sector %llu on %s).\n",
+ mdname(conf->mddev),
+ (unsigned long long)(sh->sector
+ + rdev->data_offset),
+ bdn);
else if (atomic_read(&rdev->read_errors)
> conf->max_nr_stripes)
printk(KERN_WARNING
OpenPOWER on IntegriCloud