summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorThomas Renninger <trenn@suse.de>2005-12-21 01:29:00 -0500
committerLen Brown <len.brown@intel.com>2005-12-22 22:00:25 -0500
commit75b245b3259133360845bc6de3aecb8a6bd6ab59 (patch)
tree75db01d92dd957a2508b2c4c5bca501b75e9527d
parentb05948d9b7167e23af88cc65b9ffa4687eaf1f0d (diff)
downloadblackbird-op-linux-75b245b3259133360845bc6de3aecb8a6bd6ab59.tar.gz
blackbird-op-linux-75b245b3259133360845bc6de3aecb8a6bd6ab59.zip
[ACPI] fix passive cooling regression
Return logic was inverted. Going for changing the return value to not return zero as it is makes more sense regarding the naming of the function (cpu_has_cpufreq()). http://bugzilla.kernel.org/show_bug.cgi?id=3410 Signed-off-by: Thomas Renninger <trenn@suse.de> Signed-off-by: Len Brown <len.brown@intel.com>
-rw-r--r--drivers/acpi/processor_thermal.c4
1 files changed, 2 insertions, 2 deletions
diff --git a/drivers/acpi/processor_thermal.c b/drivers/acpi/processor_thermal.c
index f37584015324..dc9817cfb882 100644
--- a/drivers/acpi/processor_thermal.c
+++ b/drivers/acpi/processor_thermal.c
@@ -102,8 +102,8 @@ static int cpu_has_cpufreq(unsigned int cpu)
{
struct cpufreq_policy policy;
if (!acpi_thermal_cpufreq_is_init || cpufreq_get_policy(&policy, cpu))
- return -ENODEV;
- return 0;
+ return 0;
+ return 1;
}
static int acpi_thermal_cpufreq_increase(unsigned int cpu)