@@ -1,24 +0,0 @@
-This document contains different information about the port
-of U-Boot for the OXC board designed by Lucent Technologies,
-Inc.
-
-1. Showing activity
-
-U-Boot for the OXC board can show its current status using
-the Active LED. This feature is configured by the following
-options:
-
-CONFIG_SHOW_ACTIVITY
-
- When this option is on, the Active LED is blinking fast
-when U-Boot runs in the idle loop (i.e. waits for user
-commands from serial console) and blinking slow when it
-downloads an image over network. When U-Boot loads an image
-over serial line the Active LED does not blink and its state
-is random (i.e. either constant on or constant off).
-
-CONFIG_SHOW_BOOT_PROGRESS
-
- When this option is on, U-Boot switches the Active LED
-off before booting an image and switches it on if booting
-failed due to some reasons.