diff options
Diffstat (limited to 'net/mac80211/mesh_plink.c')
-rw-r--r-- | net/mac80211/mesh_plink.c | 47 |
1 files changed, 24 insertions, 23 deletions
diff --git a/net/mac80211/mesh_plink.c b/net/mac80211/mesh_plink.c index ae026acec874..60ef235c9d9b 100644 --- a/net/mac80211/mesh_plink.c +++ b/net/mac80211/mesh_plink.c @@ -105,15 +105,15 @@ static struct sta_info *mesh_plink_alloc(struct ieee80211_sub_if_data *sdata, return sta; } -/** mesh_set_ht_prot_mode - set correct HT protection mode +/* + * mesh_set_ht_prot_mode - set correct HT protection mode * - * Section 9.23.3.5 of IEEE 80211s standard describes the protection rules for - * HT mesh STA in a MBSS. Three HT protection modes are supported for now, - * non-HT mixed mode, 20MHz-protection and no-protection mode. non-HT mixed - * mode is selected if any non-HT peers are present in our MBSS. - * 20MHz-protection mode is selected if all peers in our 20/40MHz MBSS support - * HT and atleast one HT20 peer is present. Otherwise no-protection mode is - * selected. + * Section 9.23.3.5 of IEEE 80211-2012 describes the protection rules for HT + * mesh STA in a MBSS. Three HT protection modes are supported for now, non-HT + * mixed mode, 20MHz-protection and no-protection mode. non-HT mixed mode is + * selected if any non-HT peers are present in our MBSS. 20MHz-protection mode + * is selected if all peers in our 20/40MHz MBSS support HT and atleast one + * HT20 peer is present. Otherwise no-protection mode is selected. */ static u32 mesh_set_ht_prot_mode(struct ieee80211_sub_if_data *sdata) { @@ -128,21 +128,22 @@ static u32 mesh_set_ht_prot_mode(struct ieee80211_sub_if_data *sdata) rcu_read_lock(); list_for_each_entry_rcu(sta, &local->sta_list, list) { - if (sdata == sta->sdata && - sta->plink_state == NL80211_PLINK_ESTAB) { - switch (sta->ch_type) { - case NL80211_CHAN_NO_HT: - mpl_dbg("mesh_plink %pM: nonHT sta (%pM) is present", - sdata->vif.addr, sta->sta.addr); - non_ht_sta = true; - goto out; - case NL80211_CHAN_HT20: - mpl_dbg("mesh_plink %pM: HT20 sta (%pM) is present", - sdata->vif.addr, sta->sta.addr); - ht20_sta = true; - default: - break; - } + if (sdata != sta->sdata || + sta->plink_state != NL80211_PLINK_ESTAB) + continue; + + switch (sta->ch_type) { + case NL80211_CHAN_NO_HT: + mpl_dbg("mesh_plink %pM: nonHT sta (%pM) is present", + sdata->vif.addr, sta->sta.addr); + non_ht_sta = true; + goto out; + case NL80211_CHAN_HT20: + mpl_dbg("mesh_plink %pM: HT20 sta (%pM) is present", + sdata->vif.addr, sta->sta.addr); + ht20_sta = true; + default: + break; } } out: |