| Commit message (Collapse) | Author | Age | Files | Lines |
... | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Applied the normal parent/child rules for EC/EX/EQ logic to be done in
the runtime deconfig logic.
After applying the deconfig logic, then reset the PM for the parent
proc of the EX/EX/EQ.
To facilitate the code changes, modified the return value of the
TARGETING::getParent(...) call. It no longer returns a const * Target,
considering 5 times out of 7 of it's usage, users were just
staic_cast(ing) away the const.
Clear out the HB reset attribute in the mpipl path.
Modify PRD logic to use runtime deconfig call in malfunction alert
path.
CMVC-Prereq: 1066157
Change-Id: If81f2f15c6e84bf2adb6fd66c1321b8f1ddf1a86
CQ: SW443157
Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/64873
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Roland Veloz <rveloz@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
- The Port number was causing dual drop dimm configs to lose
half of their dimms during MRW processing
Change-Id: Ie5b6f3a4bd9dc9f8792d3a262a8fbcdaf7c6f7e1
CQ: SW443160
Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/65096
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com>
Reviewed-by: Prachi Gupta <pragupta@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Adding support for Cumulus DD1.3 SBE images in the FSP PNOR
Dropping support for Cumulus DD1.0 SBE image from FSP PNOR
CMVC-Prereq: 1060757
CMVC-Prereq: 1063108
CMVC-Prereq: 1061378
Change-Id: Ia315c6f786ef6c522acf4e580ad435b0180513b3
Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/62636
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Modified processMrw.pl to track sensor IDs seen, and to error out
if the same sensor ID is seen more than once.
Resolves: #75
Change-Id: Ic8b9aae67ae037acc771cac6c8920dfcfba7515e
Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/64047
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
Reviewed-by: Roland Veloz <rveloz@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
hwsvd crash observed during handling hbrt message to get
tod topology data because allocated size was based on a
hardcoded value for max_compute_nodes_per_system
Change-Id: I587dac32fab9dd67fe96e213c5ef72626e4e2ea1
CQ:SW434860
CMVC-Coreq: 1059506
Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/64459
Reviewed-by: Roland Veloz <rveloz@us.ibm.com>
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Reviewed-by: Prachi Gupta <pragupta@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
In Axone we are introducing a new memory buffer known as the Open
Capi Memory Buffer chip. On this chip will be a MEM_PORT chiplet(s)
which will connect to the DIMM. This completes the following picture
(it is expected OMIC, MCC, and OMI have been added already)
MI--MCC
/ \
Proc--MC < __ OMI--OCMB--MEM_PORT--DIMM
\ /
OMIC
Change-Id: I1a3e3d38978ce11fecee2ab11de83909eb440774
RTC:172970
Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/63911
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
Reviewed-by: Prachi Gupta <pragupta@us.ibm.com>
Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Added 3 new target types to start things off. These are the OMI
(open-capi memory interface), the OMIC (open-capi memory interface
controller), and the MCC (memory channel controller). These new
targets will help us represent the new memory complex we are using
for axone. The axone memory hiearchy will look like this:
MI--MCC
/ \
Proc--MC < __ OMI--OCMB--MEMPORT--DIMM
\ /
OMIC
**Note that OCMB/MEMPORT have not been implemented in hostboot yet
Change-Id: I3df4eb3e279f825f0bdee86448ea23cb975e5511
RTC:172969
Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/63744
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
Reviewed-by: Prachi Gupta <pragupta@us.ibm.com>
Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
| |
Change-Id: Iba4a7eb7d946b46cf94ef0f1dd6505dc41d35c1a
Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/63930
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Change-Id: Ic4e33d1a950716879521444abf633287290b9c52
CQ:SW440238
Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/63541
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
Reviewed-by: Louis Stermole <stermole@us.ibm.com>
Reviewed-by: ANUWAT SAETOW <asaetow@us.ibm.com>
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Dev-Ready: STEPHEN GLANCY <sglancy@us.ibm.com>
Reviewed-by: ANDRE A. MARIN <aamarin@us.ibm.com>
Tested-by: HWSV CI <hwsv-ci+hostboot@us.ibm.com>
Tested-by: Hostboot CI <hostboot-ci+hostboot@us.ibm.com>
Reviewed-by: Jennifer A. Stofer <stofer@us.ibm.com>
Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/63552
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
When we changed the fleetwood proc numbering to match cronus, we
didn't update the proc numbering for wrap mode. This lead to weird
behaviours, like proc0 was treated as alt master or booting off a
completely wrong proc (proc 3).
Change-Id: Ia91b10d6e52e6f2e7b36ee59e109133c72bd7372
CQ:SW439810
Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/63488
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com>
Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com>
Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
This change amends the processMrw.pl script to get the I2C_ADDRESS property
from the I2C slave if it is not available from the I2C bus object. Without
this change, the OpenPOWER MRWs populate invalid I2C addresses in the
HDAT I2C attributes, which Hostboot then ignores, resulting in OS not seeing
all the I2C devices
Change-Id: I6a5f1193f31b124193641174229b5f9433b41d4c
CQ: SW438846
Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/62968
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
MDRT count is saved out into an attribute in istep14 and the same
is fetched out in istep21 for Phyp as well as Opal(ZZ-L) system.
Added libruntime.so to istep14, Since Dump relies upon runtime module
Moved 'useRelocatedPayloadAddr' setting to call_host_mpipl_service(),
So that we have everything set before calling doDumpCollect()
Change-Id: I5d30135d86a1477a68509aaff0516efb4d620410
Signed-off-by: Vasant Hegde <hegdevasant@linux.vnet.ibm.com>
Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/58636
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
In the event that the SBE fails hostboot will attempt to recover it.
During runtime hostboot will attempt an HRESET if the SBE is in a
failed state. When the SBE performs the HRESET it will save some
important information that will persist through the reset. If one
side is failing to recover the retry code will attempt to switch sides
and do the hreset. If the SBE seeproms have different versions of the
SBE code the data that was supposed to persist through the HRESET will
be in incorrect places because the version mismatch. Because of this
we cannot switch seeprom sides and perform a hreset if the seeproms have
different level of the SBE code.
CQ: SW438029
Change-Id: Ic7078a886088cc4d5355cc076e72d0fc36f85027
Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/61605
Reviewed-by: Matt Derksen <mderkse1@us.ibm.com>
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Create CFM attribute and target xml files.
Used for Concurrent Firmware Maintenance testing.
Change-Id: Ie2c1fe468bb533f40863a1b15a2cb9577eeb6220
RTC:181484
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/62027
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com>
Reviewed-by: Prachi Gupta <pragupta@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
This commit adds PEER_TARGET and PEER_PATH to the SMPGROUP Target,
which is a child of the OBUS chiplet. This should resolve the
PEER_PATH not being set for some instances of the SMPGROUP.
Change-Id: Ifa96837c446b45d58ba60d759ba78df1f553d363
RTC:184518
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/62351
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Need to ensure REL_POS is the logical position of the
target unit relative to its immediate parent.
This change affects the REL_POS of the following units:
EX,CORE,MCS,MCA,MC,MI,DMI,OBUS_BRICK,SMPGROUP
Change-Id: I416aa7fe312a995d10fc181da6d6356258a7e001
CQ:SW435611
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/61568
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Prachi Gupta <pragupta@us.ibm.com>
Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Change-Id: I55a1e6f87730eaa8d8f40b54b8cd28fb3040230e
CQ: SW435561
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/61934
Reviewed-by: MURULIDHAR NATARAJU <murulidhar@in.ibm.com>
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Sachin Gupta <sgupta2m@in.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Some of the usage of FAPI attributes on FSP which marked
non syncable was not detected, now GETMACRO is generated on
FSP only if the attribute is not on the non-sync list.
Change-Id: I0969ae802f13b65c80e96dbbf1a210ee8454685f
CQ: SW433656
CMVC-Prereq: 1058619
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/60861
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
An OBUS has 2 smpgroup targets and 3 brick targets under it. To
make sure that the parent OBUS does get deconfigured when the
child SMPGROUP targets are gone (and if the OBUS is used ONLY for
SMP) we need to get the brick targets under the OBUS deconfigured.
Add new DECONFIGURED_BY_OBUS_MODE for this case
Change-Id: I358a16c2b480c15f48c3dd591ba593225701a97f
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/61746
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Reviewed-by: Sachin Gupta <sgupta2m@in.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Prachi Gupta <pragupta@us.ibm.com>
Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Update the no sync attribute xml with a new tag indicating
whether the compile time check for usage on fsp should be
skipped.
Change-Id: I9532485b41b89a437914aade312d598a5e4a52b1
CMVC-Prereq: 1060012
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/61454
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Sachin Gupta <sgupta2m@in.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
| |
Change-Id: I3eba09cf3552cfa6592a3771910a94122b307041
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/60376
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: VENKATESH SAINATH <venkatesh.sainath@in.ibm.com>
Disable-CI: NAGENDRA K. GURRAM <nagendra.g@in.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Change-Id: I0c26630e422dee9722a2876c2eb6d7ce3b76ff88
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/60352
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: VENKATESH SAINATH <venkatesh.sainath@in.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
Disable-CI: NAGENDRA K. GURRAM <nagendra.g@in.ibm.com>
Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
-In order to support bifurcation of slot P1-C3 in the shark
platform changes were needed to the xml parsing so that
several key attributres would be populated.
Change-Id: Id0792cbf15a0cb844b63f8821f7c0a60bdfd5ea2
RTC:192871
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/60101
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Prachi Gupta <pragupta@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Change-Id: I991ca639d2917c2618dbf3eec65347bd794c2356
RTC:175881
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/61257
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Roland Veloz <rveloz@us.ibm.com>
Reviewed-by: Prachi Gupta <pragupta@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
I saw the EKB developers removed this unused attribute so I am
removing it from our customized list to reduce the clutter
Change-Id: If5925490e8bee6a23d5572c25ad707174f0426ef
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/61073
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Prachi Gupta <pragupta@us.ibm.com>
Reviewed-by: Richard Ward <rward15@us.ibm.com>
Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
The memory targets should have HUID's that are relative
to the node they are in.
Change-Id: I1245c07f1bb9cff35f5bea46fca3b490d0be700f
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59884
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Prachi Gupta <pragupta@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Rework the code in the runtime startup() function to not depend on using
Node 0 reserved memory data to discover what nodes are present and to create
"invalid node" structs in iv_nodeContainer for nodes that are not present.
Change-Id: I61f0dbdc94c6dd1a31a3e3453b149e7322311a6e
RTC: 192967
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59497
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com>
Reviewed-by: Prachi Gupta <pragupta@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
During Hostboot IPL time we do not know about other node's OBUSes
so the PEER_TARGET attribute on the OBUS targets should be NULL.
During HBRT init we will gain information about other node's OBUS
targets so we will write the correct values during HBRT init. During
MPIPL we must again adjust the PEER_TARGET values as the virtual
memory map changes. There was a bug for the MPIPL side of things where
we were not writing NULL to the OBUS's PEER_TARGET attribute when
we should have. Writing NULL is correct because Hostboot is unaware
of where the OBUS target is in memory during IPL time. The correct
address will get written into the attribute during HBRT init after
the MPIPL completes.
Change-Id: I790d8f6b237d0ccddbb57680feb5d331dd1fa471
CQ: SW433560
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/60967
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Roland Veloz <rveloz@us.ibm.com>
Reviewed-by: Prachi Gupta <pragupta@us.ibm.com>
Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
| |
Change-Id: I2846800bf8b9b9e6df5dc3c1581bfd7eae80c306
RTC:190805
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/60444
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
There are currently two competing sets of attributes related to
the DIMM position.
- Legacy (P8) MBA_PORT/MBA_DIMM
- New (P9) CEN_MBA_PORT/CEN_MBA_DIMM
These two sets of attributes are not currently being populated
with the same data in all of the MRW xml files. The P9 HWPs are
using the CEN_ versions but there is a lot of code on the FSP
that is still using the old versions. Additionally, the Nimbus
MRW XMLs are using MBA_PORT to represent the dimm position
behind the MCA (even though there is only a single port on the
MCA and MBA is erroneous).
This commit attempts to consolidate things into a new set of
more generic (and hopefully more descriptive) attributes to use
for all system types. The MRW parsing logic has been modified
to consume whatever data it can to populate all 3 sets of data
with the same values. Eventually we will deprecate the 2
previous attribute sets once we've cleaned all the existing files
up.
The new attributes are:
- MEM_PORT
- POS_ON_MEM_PORT
CQ: SW430317
Change-Id: If63929d78dcaacc1120709a659d6094ce576918d
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59077
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Andrew J. Geissler <andrewg@us.ibm.com>
Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
| |
Change-Id: I12a3658baac34a10e2570f360ed61767b5377855
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/60664
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
Tested-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
The HUID is composed of multiple pieces:
SSSS NNNN TTTTTTTT IIIIIIIIIIIIIII
SSSS : System instance
NNNN : Node instance
TTTTTTTT : Target type
IIIIIIIIIIIIIII : Instance number (relative to node contained in)
The current code correctly places the node number in the HUID
but it uses an instance value relative to the entire system,
instead of just the specific node.
Targets affected by this change are:
- Processors
- All chiplets within processors
A future change will be made to fix up the memory subsystem
Change-Id: I25f0e23832ead80e54ca3960930d83792f3a80aa
CQ:SW425239
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59276
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
Reviewed-by: Prachi Gupta <pragupta@us.ibm.com>
Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com>
Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
| |
Change-Id: I0553003dc8776edf6dd4ffa4e57b441f4e5cff3b
RTC:192605
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/60095
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
This commit adds attributes for the ATTN areas that hostboot
intends to open up for PHYP that FSP can read for awareness.
Change-Id: I6371665b08c0ab082e467fc3bec96503f54f8dd3
RTC:186439
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59903
Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com>
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
This is needed to support SMP endpoint deconfiguration
Change-Id: I6abbd6717d2fb4f32813681f94318779b783748f
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/60064
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: DHRUVARAJ SUBHASH CHANDRAN <dhruvaraj@in.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
| |
Change-Id: Iece3678f64ef623464144b3f6a189d0516e01564
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59313
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
There are two cases where hostboot's attention is required in istep7:
- If HRMOR we booted with doesn't fall in the range of proc_mem_to_use's
memory, then the SBE is old. HB will do an sbe update and
request re-ipl
- If HB deconfigured a bunch of dimms in istep7 and ran out of memory,
then we will request a reconfig loop
Then, in istep14, we added another sanity check to make sure we have
memory as expected to prevent unexpected failure after exiting cache
contained mode.
Change-Id: I018f4ce862cc79b5d7bacbe01cc28d1d2b4fc788
CQ:SW430015
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59696
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
- Force TPM_REQUIRED to 1 in various XML models (by not overriding default)
- Remove old reference to SECUREBOOT_BEST_EFFORT policy in HBConfig
- Double initial TPM log size
Change-Id: Ibc9a2075ec5e490a876415d5743da40984f172f7
RTC: 187292
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59776
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com>
Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
There are a couple of things we have to do to targets/attrs when we
either transition from Hostboot->HBRT or from HBRT->Hostboot during
an MPIPL. These include resetting all of the mutex attrs so they
are in the unlocked state and updating the pointer which PEER_TARGET
stores as a value to reflect the change in the memory mapping. For
both of these tasks we need to loop through all of the targets.This
refactor allows both these tasks to be done in the same loop.
Change-Id: I23614bba11b2c9eabb97a7ddc7a53937f83dc131
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/58316
Reviewed-by: Martin Gloff <mgloff@us.ibm.com>
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Benjamin J. Weisenbeck <bweisenb@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Structure sbeCapabilities_t was added to the sbe_utils.H, a common file that
can be shared among other files that need the sbeCapabilities_t struct.
The psuCommand structure was updated, in file sbe_psudd.H, to facilitate the
PSU call to get SBE Capabilities. Also structs fifoGetCapabilitiesResponse/
fifoGetCapabilitiesRequest were added to file sbe_fifodd to facilitate
the FIFO call to get SBE Capabilities.
Attributes SBE_COMMIT_ID, SBE_VERSION_INFO and SBE_RELEASE_TAGS were added to
the target '<id>chip-processor</id>'. These attributes are the ultimate
receiver of the SBE capabilities' version, commit id and release tags info.
New file sbe_capabilities.C contains the call to getPsuSbeCapabilities and
getFifoSbeCapabilities which ultimately perform the call to do the PSU chip
operation, FIFO chip operation and update the attributes above. In step 6,
host_discover_targets, and in step 8,
call_proc_check_slave_sbe_seeprom_complete, is where the calls to
getPsuSbeCapabilities and getFifoSbeCapabilities are made respectively.
The file FipS_SBE_Interface_Specification_v1.3a.pdf (FIFO), file
Host_SBE_Interface_Specification_v0.9d.pdf and looking at
HW code were used to guide the coding of this.
Change-Id: I32ccdeab7bf0a478298b199d42d74650a3f393f6
RTC:181139
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56317
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Reviewed-by: Martin Gloff <mgloff@us.ibm.com>
Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Prachi Gupta <pragupta@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
This commit adds the attributes needed for a mutex XBUS and ABUS lock
and then uses them in the Node Communications Device Driver. It also
adds some additional error recovery to the Node Comm DD. Plus, it adds
some additional SCOMs to the Read and Write Node Comm DD operations.
Change-Id: I27b94f29a6e3c2e3e2ba98fec48cc000c39add47
RTC:191008
Depends-on:I19510888c0922e5bb857cffc9426399e79e113ba
Depends-on:I11893af06b7a097b43106117d648e9a431c4f3ea
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59292
Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com>
Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com>
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
"range" tags in attribute type definitions need to be outside of
the "simpleType" tags for the xmltohb.pl parser to recognize
and process them correctly. This change factors out the range
tags from under simpleType tags.
Change-Id: Idf023e7ff036457cefcd4f32fbf00fd176eb4b92
RTC: 191163
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59460
Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com>
Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com>
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
- Need to account for a Service Processor Fail-Over scenario
where the 'master' processor could change. Because of this, FW
must re-evaluate which target pointer is the current master
and update attributes accordingly.
Change-Id: I83ada72389f05cc2a80d4c6a34db7d9ab3c2b3ce
CQ: SW429022
RTC: 182718
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59221
Reviewed-by: Richard J. Knight <rjknight@us.ibm.com>
Reviewed-by: Prachi Gupta <pragupta@us.ibm.com>
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
In the Resource Recovery redesign, the Block Spec Deconfig attribute gets set
when a check for minimal hardware fails to find enough hardware, and it gets
cleared when there is a hardware change. Now, the Block Spec Deconfig attribute
will also be cleared when a target that had gard applied no longer has any gard
records.
Change-Id: I8f93ca4821b1360638a94855c0aadb3dda365046
CQ: SW429890
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59325
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Reviewed-by: Brian E. Bakke <bbakke@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Reviewed-by: Thi N. Tran <thi@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Currently the SMPGROUP targets under the OBUS BRICK gets the same
INSTANCE_PATH as the parent brick. This messes up the HUID-NID
mapping table needed for SMP endpoint deconfig efforts.
Change-Id: Id00cb695378d95bac473cf7a09531ce7c1f8354c
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59246
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
HWSV uses the following voltage rail ID attributes to determine the
right FSP_DEVICE_PATH (i2c path) and calls the power api to set the
voltages for each of the rails correctly. Since, all the IDs were 0,
we were setting only proc0/membuf0's voltages correctly. Everyone
else was getting standby voltage. This change looks at the vrm
connectors in the system xml and use their position as the voltage
rail IDs as they are unique per node, which is what HWSV is expecting.
The rails are: VDD_ID/VCS_ID/VDN_ID/VDDR_ID/VPP_ID/etc.
Change-Id: Ib23eaa43045fa77137c5ce5e477d007bf0c757dc
CQ:SW428817
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59140
Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com>
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Roland Veloz <rveloz@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Added logic to include the proc # in the affinity
path for TPMs. This change is required by HWSV
for TPM alignment check.
Change-Id: Ie92b57cab6dc64ae13cee25fba4169cd9a5f99ca
RTC:191163
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/58992
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com>
Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com>
Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
A_REPAIR_THRESHOLD_FIELD
A_REPAIR_THRESHOLD_MNFG
Change-Id: I19caff6441699c544600aab96c2d47542cc8cb8e
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59075
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
This is 1st phase which adds an Attribute as a container to
preserve the calculated addresses across an MPIPL.
Change-Id: I610b11b320331a82260fe790a8680a2a98bf992b
RTC:191463
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/58942
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Prachi Gupta <pragupta@us.ibm.com>
Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
This commit adds an option to the two masterProcChipTargetHandle()
functions to only look for and return a functional master proc chip
as necessary with the issue in Defect SW424528. The default behavior
of these functions - where the functionality is not checked - remains
the same. Once use of these functions has also been updated to use
this new option.
Change-Id: I37049d2cb9299a9404b57d85031a364bdb257c82
CQ:SW424528
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/58920
Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com>
Reviewed-by: Marshall J. Wilks <mjwilks@us.ibm.com>
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Reviewed-by: Sachin Gupta <sgupta2m@in.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|