summaryrefslogtreecommitdiffstats
path: root/llvm/test/CodeGen/PowerPC/crbits.ll
Commit message (Collapse)AuthorAgeFilesLines
* [PowerPC] Enable printing instructions using aliasesHal Finkel2015-04-231-1/+1
| | | | | | | | | | | TableGen had been nicely generating code to print a number of instructions using shorter aliases (and PowerPC has plenty of short mnemonics), but we were not calling it. For some of the aliases we support in the parser, TableGen can't infer the "inverse" alias relationship, so there is still more to do. Thus, after some hours of updating test cases... llvm-svn: 235616
* [opaque pointer type] Add textual IR support for explicit type parameter to ↵David Blaikie2015-02-271-1/+1
| | | | | | | | | | | | | | | | | | | | | | | | load instruction Essentially the same as the GEP change in r230786. A similar migration script can be used to update test cases, though a few more test case improvements/changes were required this time around: (r229269-r229278) import fileinput import sys import re pat = re.compile(r"((?:=|:|^)\s*load (?:atomic )?(?:volatile )?(.*?))(| addrspace\(\d+\) *)\*($| *(?:%|@|null|undef|blockaddress|getelementptr|addrspacecast|bitcast|inttoptr|\[\[[a-zA-Z]|\{\{).*$)") for line in sys.stdin: sys.stdout.write(re.sub(pat, r"\1, \2\3*\4", line)) Reviewers: rafael, dexonsmith, grosser Differential Revision: http://reviews.llvm.org/D7649 llvm-svn: 230794
* Remove extra truncs/exts around i32 bit operations on PPC64Hal Finkel2014-03-011-2/+30
| | | | | | | | | | | | | | | | | | | | | | | | | This generalizes the code to eliminate extra truncs/exts around i1 bit operations to also do the same on PPC64 for i32 bit operations. This eliminates a fairly prevalent code wart: int foo(int a) { return a == 5 ? 7 : 8; } On PPC64, because of the extension implied by the ABI, this would generate: cmplwi 0, 3, 5 li 12, 8 li 4, 7 isel 3, 4, 12, 2 rldicl 3, 3, 0, 32 blr where the 'rldicl 3, 3, 0, 32', the extension, is completely unnecessary. At least for the single-BB case (which is all that the DAG combine mechanism can handle), this unnecessary extension is no longer generated. llvm-svn: 202600
* Swap PPC isel operands to allow for 0-foldingHal Finkel2014-02-281-27/+17
| | | | | | | | | The PPC isel instruction can fold 0 into the first operand (thus eliminating the need to materialize a zero-containing register when the 'true' result of the isel is 0). When the isel is fed by a bit register operation that we can invert, do so as part of the bit-register-operation peephole routine. llvm-svn: 202469
* Add CR-bit tracking to the PowerPC backend for i1 valuesHal Finkel2014-02-281-0/+174
This change enables tracking i1 values in the PowerPC backend using the condition register bits. These bits can be treated on PowerPC as separate registers; individual bit operations (and, or, xor, etc.) are supported. Tracking booleans in CR bits has several advantages: - Reduction in register pressure (because we no longer need GPRs to store boolean values). - Logical operations on booleans can be handled more efficiently; we used to have to move all results from comparisons into GPRs, perform promoted logical operations in GPRs, and then move the result back into condition register bits to be used by conditional branches. This can be very inefficient, because the throughput of these CR <-> GPR moves have high latency and low throughput (especially when other associated instructions are accounted for). - On the POWER7 and similar cores, we can increase total throughput by using the CR bits. CR bit operations have a dedicated functional unit. Most of this is more-or-less mechanical: Adjustments were needed in the calling-convention code, support was added for spilling/restoring individual condition-register bits, and conditional branch instruction definitions taking specific CR bits were added (plus patterns and code for generating bit-level operations). This is enabled by default when running at -O2 and higher. For -O0 and -O1, where the ability to debug is more important, this feature is disabled by default. Individual CR bits do not have assigned DWARF register numbers, and storing values in CR bits makes them invisible to the debugger. It is critical, however, that we don't move i1 values that have been promoted to larger values (such as those passed as function arguments) into bit registers only to quickly turn around and move the values back into GPRs (such as happens when values are returned by functions). A pair of target-specific DAG combines are added to remove the trunc/extends in: trunc(binary-ops(binary-ops(zext(x), zext(y)), ...) and: zext(binary-ops(binary-ops(trunc(x), trunc(y)), ...) In short, we only want to use CR bits where some of the i1 values come from comparisons or are used by conditional branches or selects. To put it another way, if we can do the entire i1 computation in GPRs, then we probably should (on the POWER7, the GPR-operation throughput is higher, and for all cores, the CR <-> GPR moves are expensive). POWER7 test-suite performance results (from 10 runs in each configuration): SingleSource/Benchmarks/Misc/mandel-2: 35% speedup MultiSource/Benchmarks/Prolangs-C++/city/city: 21% speedup MultiSource/Benchmarks/MiBench/automotive-susan: 23% speedup SingleSource/Benchmarks/CoyoteBench/huffbench: 13% speedup SingleSource/Benchmarks/Misc-C++/Large/sphereflake: 13% speedup SingleSource/Benchmarks/Misc-C++/mandel-text: 10% speedup SingleSource/Benchmarks/Misc-C++-EH/spirit: 10% slowdown MultiSource/Applications/lemon/lemon: 8% slowdown llvm-svn: 202451
OpenPOWER on IntegriCloud